PRECISION DME FOR NEW LANDING SYSTEM: FAST OR SLOW PULSE?

Recent proposals for the new precision distance measuring equipment to be collocated with the proposed microwave landing system are based on two main techniques: the fast and slow pulse. This paper analyzes the factors involved in using both these techniques and compares the anticipated costs. Comparison shows that the fast pulse method will probably have technical and economic advantages over the slow pulse technique.