Guide for Using Autoclaved Aerated Concrete Panels: I - Structural Design

The paper provides an overview of ACI 523.5R, a guide for using autoclaved aerated concrete (AAC) panels. The guide's design provisions are non-mandatory and are a synthesis of design recommendations from the Autoclaved Aerated Concrete Products Association and previously conducted research. The design equations discussed include flexural, axial compression, shear, bearing, bond and development of reinforcement and special seidmic design.

Language

  • English

Media Info

  • Media Type: Print
  • Features: Figures; References;
  • Pagination: pp 17-28
  • Monograph Title: Autoclaved Aerated Concrete - Properties and Structural Design

Subject/Index Terms

Filing Info

  • Accession Number: 01003590
  • Record Type: Publication
  • ISBN: 0870311751
  • Files: TRIS
  • Created Date: Aug 12 2005 10:12AM