FAILURE ANALYSIS OF THE HOAN BRIDGE FRACTURES
The northbound approach span of the Hoan Bridge on I-794 in Milwaukee, Wisconsin, failed by brittle fracture on December 13, 2000. Two of 3 welded plate girders of the 66.45 m approach end span were fractured full depth leaving only 1 partially cracked girder supporting the span. The failure assessment is summarized.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/isbn/9058096068
-
Corporate Authors:
Swets & Zeitlinger Publishers
Heereweg 347-B
2161 CA Lisse, Netherlands -
Authors:
- Wright, W J
- Fisher, J W
- Kaufmann, E J
-
Conference:
- Recent Developments in Bridge Engineering. Proceedings of the Second New York City Bridge Conference
- Location: New York, NY
- Date: 2003-10-20 to 2003-10-21
- Publication Date: 2003
Language
- English
Media Info
- Features: Figures; Photos; References;
- Pagination: p. 179-192
Subject/Index Terms
- TRT Terms: Bridge engineering; Bridge members; Brittleness; Failure analysis; Highway bridges; Plate girders; Structural deterioration and defects; Welded plates
- Identifier Terms: Hoan Bridge (Wisconsin)
- Geographic Terms: Milwaukee (Wisconsin)
- Subject Areas: Bridges and other structures; Design; Highways; I24: Design of Bridges and Retaining Walls;