UNLOADING OF THE RAILROAD NETWORK BY THE SINGLE-PHASE STATIC CONVERTER WITH 2-C-LUB CIRCUIT
BAHNNETZENTLASTUNG DURCH EINPHASEN-STROMRICHTER MIT 2-C-LUB- SCHALTUNG
2-C-LUB is a quenching unsymmetrical bridge circuit with two quenching capacitors. Results of test drives with the locomotive 181,208 are reported for two cases. In one, the 2-C-LUB circuit was incorporated while in the other it was left out. These test runs have shown that a considerable reduction of network loading was realized by the incorporation of the 2-C-LUB circuit because of the large decrease of the effective value of the overcurrent and the resultant improvement of the power factor.
-
Corporate Authors:
Elitera Verlag
Fritz-Wildungstrasse 22
1 Berlin 33, Germany -
Authors:
- Knuth, Dean
- Schwarzenau, R
- Publication Date: 1976
Language
- German
Media Info
- Features: References;
- Pagination: p. 49-54
-
Serial:
- Technische Mitteilungen AEG-Telefunken
- Volume: 66
- Issue Number: 1
- Publisher: Allgemeine Elektricitaets Gesellschaft-Telefunken
Subject/Index Terms
- TRT Terms: Converters (Electricity); Electric locomotives; Electric power supply; Power factor (Electricity); Solid state devices
- Uncontrolled Terms: Propulsion systems
- Old TRIS Terms: Converters; Power factor; Solid state
- Subject Areas: Energy; Railroads;
Filing Info
- Accession Number: 00149397
- Record Type: Publication
- Source Agency: Engineering Index
- Files: TRIS
- Created Date: Apr 27 1977 12:00AM