THE CORRELATION BETWEEN WATER TREATMENT AND SCALING OF 100 KG/SQCM PRESSURE MARINE BOILERS

After 8 years of operation of the 100 kg/sqcm class marine boilers installed on the tanker "Idemitsu Maru", the max inner scale mass is only about 50 mg/sqcm and the location is the fire-side of rear water wall panel, 3300-3400 mm height from furnace floor level. The alkali corrosion on the inner surface of boiler tubes after descaling is not observed at all.