The scanning electron microscope (SEM) with its large depth of field, wide range of magnification, and ease of operation is a powerful tool for analyzing structural failures. It is, however, just one of a number of tools and techniques available for failure analysis and associated service, production, quality control, engineering, or research problems. For successful utilization, the SEM must be part of an overall integrated analytical technique which combines electron and optical microscopy, microprobe, X-ray diffraction, and metallography. By using an integrated approach the macro and microtropography of fracture surfaces can be characterized and correlated with the chemistry of surface deposits and microstructure. This information correlated with service history, alloy composition and heat treatment often provides an answer as to why a part has failed. /Author/