APPLICATION OF HIGH STRENGTH AND SELF-COMPACTING CONCRETE FOR CONTINUOUS DIAPHRAGM WALLS

Newly developed self-compacting concrete having required strength of 80 N/(mm square) was used in construction of continuous underground diaphragm walls. The laboratory test results on material selection and mix proportioning of the concrete are reported. Also discussed are the site investigations on the quality control procedures in manufacturing concrete and physical properties of the concrete cast in the structure.

Language

  • English

Media Info

  • Features: Figures; Photos; References; Tables;
  • Pagination: p. 622-635