THE STRENGTH OF FISH-BOLTS
A report on performance of hardened and non-hardened fish bolts, also bending-free bolts are included. Tests included the use of Vibrogir to determine the effect of vibration in the loosening of a rail-fish plate and bolt unit. Under the equivalent of a passage of 85 million tons, no looseness because of nut turning was found.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/oclc/3127232
-
Corporate Authors:
JAPANESE NATIONAL RAILWAYS
TOKYO, Japan -
Authors:
- Umekubo, S
- Publication Date: 1965-6
Media Info
- Pagination: p. 23-26
-
Serial:
- Railway Technical Research Institute, Quarterly Reports
- Volume: 6
- Issue Number: 2
- Publisher: Railway Technical Research Institute/Tetsudo Gijutsu Kenkyujo
- ISSN: 0033-9008
- Serial URL: http://www.rtri.or.jp/eng/
Subject/Index Terms
- TRT Terms: Bending; Bending stress; Bolts; Equipment tests; Failure; Fastenings; Holes; Rail (Railroads); Rail joints; Stresses; Technology; Tie bars
- Geographic Terms: Japan
- Old TRIS Terms: Bolt holes; End breaks; Rail failure; Test equipment; Vibrogir
- Subject Areas: Materials; Railroads;