INTRINSIC DAMPING IN BASIC MAGNETIC LEVITATION SYSTEMS WITH A CONTINUOUS SHEET TRACK

Previous work on basic magnetic levitation systems is extended to analyze vertical and lateral intrinsic damping in these systems under the assumption that quasi-static forces remain essentially unchanged in dynamic situations caused by small vertical and/or transverse perturbations. The analysis shows that the intrinsic damping is quite small.

  • Corporate Authors:

    Siemens, AC

    Postfach 325
    852 Erlangen 2,   Germany 
  • Authors:
    • Urankar, L
  • Publication Date: 1976

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00141110
  • Record Type: Publication
  • Source Agency: Engineering Index
  • Report/Paper Numbers: R&D Rept.
  • Files: TRIS
  • Created Date: Oct 26 1976 12:00AM