RESID DESULFURIZATION -- CONCLUSION: SIMPLE CHANGES REDUCE CATALYST DEACTIVATION, PRESSURE-DROP BUILDUP
A Japanese refiner learned how changing the catalyst combination and bed temperature in its resid HDS unit corrected operational problems.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/issn/00301388
-
Corporate Authors:
PennWell Publishing Company
1421 South Sheridan, P.O. Box 1260
Tulsa, OK United States 74101 -
Authors:
- Koyama, H
- Nagai, E
- Torii, H
- Kumagai, H
- Publication Date: 1995-11-20
Language
- English
Media Info
- Pagination: p. 68-71
-
Serial:
- Oil and Gas Journal
- Volume: 93
- Issue Number: 47
- Publisher: PennWell Publishing Company
- ISSN: 0030-1388
Subject/Index Terms
- TRT Terms: Catalysts; Desulfurization; Residual oils; Technology
- Geographic Terms: Japan
- Old TRIS Terms: Deactivation
- Subject Areas: Highways; Materials; I31: Bituminous Binders and Materials;
Filing Info
- Accession Number: 00714695
- Record Type: Publication
- Files: TRIS
- Created Date: Dec 1 1995 12:00AM