FIRE TESTS OF CONCRETE BEAMS REINFORCED WITH EPOXY-COATED BARS

This program was carried out to determine the fire endurance of two 12-in. x 14 in. (305 x 356-mm) by 32-ft (9.8-m) long concrete beams reinforced with epoxy-coated bars. Beam A was designed in accordance with the ACI 318-83 provisions whereas Beam B with ACI 318-89 codes. Both beams were made with carbonate aggregate concrete, and subjected to fire tests following the provisions outlined in ASTM E 119. During the fire test the beam was loaded to simulate the end span of a continuous beam, such that the applied moments at mid-span and over the continuous support were equivalent to 40 and 50%, respectively, of the nominal moment strengths at corresponding sections. The measured fire endurances were 2 hours 33 minutes for Beam A and 3 hours 48 minutes for Beam B.

  • Corporate Authors:

    Portland Cement Association

    5420 Old Orchard Road
    Skokie, IL  United States  60077
  • Authors:
    • Lin, T D
    • Burg, R G
  • Publication Date: 1994

Language

  • English

Media Info

  • Features: Figures; Photos; References; Tables;
  • Pagination: 11 p.

Subject/Index Terms

Filing Info

  • Accession Number: 00675384
  • Record Type: Publication
  • Report/Paper Numbers: RP321, PCA R&D Serial No. 1888