BRIDGE OPENINGS

The file name is ENPOND. A program to determine bridge size required to handle flow from a given drainage area. The railroad embankment forms a dam thus creating a reservoir having a water level well above the structure, typically a multiple box, thus partially containing the inflow and increasing the capacity of the structure. Input describes the water shed, probable storm characteristics, and the reservoir. Output is the geometry of the box, or boxes, required.

  • Corporate Authors:

    Atchison, Tokeka and Santa Fe Railway

    9th and Jackson Streets, Information Systems Department
    Topeka, KS  USA  66628
  • Authors:
    • Stane, R A
  • Publication Date: 0

Subject/Index Terms

Filing Info

  • Accession Number: 00098739
  • Record Type: Publication
  • Source Agency: American Railway Engineering Association
  • Files: TRIS
  • Created Date: Aug 27 1975 12:00AM