SIGNAL INTERCONNECTED CABLE

Article describing a method of interconnecting signals together that saves costs. Vacaville, California changed the pull box intervals to a maximum of four hundred feet, or per wire manufacturers specifications. The decision was made to use a two-inch UB condulet body because it is made of malleable iron. A 3/8 inch diamond plate steel was cut and fitted to the UB condulet body as a traffic cover. These UB condulet bodies were used for a pull section only and not for splicing.

  • Availability:
  • Corporate Authors:

    International Municipal Signal Association

    165 East Union Street
    P.O. Box 539
    Newark, NY  United States  14513
  • Authors:
    • Connolly, T
  • Publication Date: 1992-5

Media Info

  • Features: Photos;
  • Pagination: p. 16
  • Serial:

Subject/Index Terms

Filing Info

  • Accession Number: 00623447
  • Record Type: Publication
  • Files: TRIS
  • Created Date: Jul 31 1992 12:00AM