INDUCTIVE EFFECT ON TELECOMMUNICATION LINES CAUSED BY A TRACTION NETWORK FED BY A 2 X 25 KV ELECTRIC SYSTEM

INDUKTIVNOE VLIJANIE TJAGOJOV SETI NA LINII SVJAZI PRI SISTEME CLEKTRIFIKACII 2 X 25 KV

The ariticle describes a method of calculating the voltage induced in telecommunication lines and other communication media, by the traction network, in the case of a 2 x 25 kV electric supply system with line autotransformers on the occasion of a forced rating or a short circuit. The calculations show that the disturbing inductive effect, sometimes dangerous, due to a traction network fed by a 2 x 25 kV alternating current system, is several times less than that of an ordinary 25 kV traction network.

  • Corporate Authors:

    All-Union Scientific Res Inst of Railroad Transp

    3-aya Mytishchinskaya Ulitsa 10
    Moscow I-164,   USSR 
  • Authors:
    • Pavlov IV
  • Publication Date: 1975

Language

  • Russian

Media Info

  • Features: References; Tables;
  • Pagination: p. 5-10
  • Serial:
    • Vestnik VNIIZT
    • Issue Number: 4
    • Publisher: All-Union Scientific Res Inst of Railroad Transp

Subject/Index Terms

Filing Info

  • Accession Number: 00129189
  • Record Type: Publication
  • Source Agency: International Union of Railways
  • Files: TRIS
  • Created Date: Feb 19 1976 12:00AM