METAL-LOSS RATES OF UNCOATED STEEL AND ALUMINUM CULVERTS IN NEW YORK

In this paper a laboratory evaluation is described of three techniques to determine metal loss on 1-in. coupons extracted from corrugated metal pipe, a field evaluation of 30 pipes to determine the sample size (number of coupons) and sampling location necessary to characterize metal loss, and a statewide survey of steel and aluminum culverts in New York. It is concluded that a pin micrometer can be used to measure metal loss and that eight coupons extracted randomly along the "worst straight line" of a pipe will provide the accuracy needed for large-scale field surveys. Results of a field survey of 190 galvanized steel culverts and 35 aluminum culverts are presented, and implementation of these results in New York is discussed.

Media Info

  • Media Type: Print
  • Features: Figures; Maps; References;
  • Pagination: pp 60-66
  • Monograph Title: Symposium on durability of culverts and storm drains
  • Serial:

Subject/Index Terms

Filing Info

  • Accession Number: 00450735
  • Record Type: Publication
  • ISBN: 0309038103
  • Files: TRIS, TRB
  • Created Date: Feb 28 1986 12:00AM