METHODS FOR DETERMINING PARTICULATE MASS AND SIZE PROPERTIES: LABORATORY AND FIELD MEASUREMENTS

Although no single particle size measuring device was found suitable in both the fine and ultrafine particle size regimes, the combination of impactors, optical counters, and diffusion batteries with condensation nuclei counters has been successfully used to measure particle size distributions and fractional efficiencies from 0.005 to 10 angstrom units in diameter.

  • Corporate Authors:

    Air Pollution Control Association

    4400 Fifth Avenue
    Pittsburgh, PA  United States  15213
  • Authors:
    • McCain, J D
    • Cushing, K M
    • Smith, W B
  • Publication Date: 1974-12

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00083903
  • Record Type: Publication
  • Source Agency: Engineering Index
  • Files: TRIS
  • Created Date: May 1 1975 12:00AM