DEEP STRUCTURES WITH PERMEABLE FOUNDATION, AUTOMATIC PUMPING STATIONS, GROUTING CURTAINS, SUBSURFACE EXPLORATION AND CALCULATION OF THE RATE OF FLOW

OUVRAGES PROFONDS A RADIERS PERMEABLES, STATIONS DE POMPAGES AUTOMATIQUES, ECRANS D'ETANCHEITE, RECONNAISSANCES IT CALCUL DES DEBITS

An example is given of an automatic pumping station, its operation, maintenance, and equipment. Vertical and horizontal curtains are described: cast-in-situ curtains and grouting curtains. Details are also given of hydrological studies (seine alluvial material, coarse limestone, false loam, auteuil sand, and plastic clay). Theoretical calculations are included.

  • Corporate Authors:

    Federation Nationale des Trav Publ & des Synd Aff

    6 Avenue Pierre Premier de Serbie
    Paris 16e,   France 
  • Authors:
    • Cardinal, J
    • Cazenove, ERV
  • Publication Date: 1971-10

Language

  • French

Media Info

  • Features: Figures; References;
  • Pagination: p. 28-37
  • Serial:
    • Travaux
    • Issue Number: 439
    • Publisher: Federation Nationale des Trav Publ & des Synd Aff

Subject/Index Terms

Filing Info

  • Accession Number: 00081149
  • Record Type: Publication
  • Source Agency: Transport and Road Research Laboratory (TRRL)
  • Files: ITRD, TRIS
  • Created Date: Apr 8 1975 12:00AM