JOINT BARS: DESIGN, SPECIFICATIONS, SERVICE TESTS, INCLUDING INSULATED JOINTS AND COMPROMISE JOINTS
Rolling-load and physical-property tests of basic-oxygen-steel joint bars, rolling-load and bend tests of three compromise joints produced by thermit welding, and a rolling-load test of an insulated joint using fiber-glass bars were investigated. Much of the work was still in progress at the time of publication. Brinell and Mechanical tests of four bars failing the rolling-load tests were tabulated and show that three of these bars were slightly harder at the top than at the bottom.
-
Corporate Authors:
American Railway Engineering Association
59 East Van Buren Street
Chicago, IL United States 60605 - Publication Date: 1962-2
Media Info
- Features: Tables;
- Pagination: p. 531-532
-
Serial:
- AREA BULLETIN
- Volume: 63 N
- Issue Number: 570
- Publisher: American Railway Engineering Association
Subject/Index Terms
- TRT Terms: Bend tests; Insulation systems; Joints (Engineering); Load tests; Signaling; Steel; Thermit welding; Tie bars
- Uncontrolled Terms: Insulated joints
- Old TRIS Terms: Slow bend tests
- Subject Areas: Bridges and other structures; Railroads;