CALCULATION OF ARMATURE TEMPERATURE RISE VALUES OF TRACTION MOTOR UNDER TRAIN OPERATING CONDITIONS
Load current for traction motors is up to 1.5 times the rated amperage over a very wide speed range, very severe operating conditions as compared with standard electric motors. Because armature construction of traction motors is complicated, localized heating can produce insulation damage. This study was to produce a method of calculating temperature rise of motors under varying operating conditions for the benefit of motor and rolling stock designers.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/oclc/3127232
-
Corporate Authors:
JAPANESE NATIONAL RAILWAYS
TOKYO, Japan -
Authors:
- YAMAZAKI, S
- Kotaki, Y
- Publication Date: 1980-9
Media Info
- Features: Figures;
- Pagination: p. 132-137
-
Serial:
- Railway Technical Research Institute, Quarterly Reports
- Volume: 21
- Issue Number: 3
- Publisher: Railway Technical Research Institute/Tetsudo Gijutsu Kenkyujo
- ISSN: 0033-9008
- Serial URL: http://www.rtri.or.jp/eng/
Subject/Index Terms
- TRT Terms: Electric insulating materials; Electric trains; Heat; Mathematical models; Traction drives; Train operations
- Candidate Terms: Electric traction
- Uncontrolled Terms: Overheating
- Old TRIS Terms: Electrical insulation; Thermal environment; Train performance
- Subject Areas: Railroads; Vehicles and Equipment;
Filing Info
- Accession Number: 00329947
- Record Type: Publication
- Files: TRIS
- Created Date: Mar 12 1981 12:00AM