Inspection of special 9150 - 60 KG/M switch design

This paper details the results of one investigation into special 9150 switches. The paper reviews current 53 Kg/m special turnout design practice, analysises turnout special determination, reviews standard 9150 - 60 Km/g switch design and investigates design of 60 Kg/m Wide Heel Switch for turnouts of fixed geometry. The paper proposes the development of more standardisation of 60 kg/m switch design and details ways of implementing this proposal.

Media Info

  • Pagination: 9p. ; PDF
  • Monograph Title: Permanent Way Institution (PWI) NSW, 1985 annual convention

Subject/Index Terms

Filing Info

  • Accession Number: 01711524
  • Record Type: Publication
  • Source Agency: ARRB
  • Files: ATRI