INVESTIGATION OF PROPRIETARY ADMIXTURES. REPORT 2. 1977-1978 TESTS

Three high-range water-reducing admixtures for concrete were tested to determine compliance with specification CRD-C 87-78 (Class A or D). One admixture met the requirements when used at a dosage to give 18 percent water reduction; the second met the requirements when used at a 12 percent water reduction, but failed to do so when used to achieve a 17 percent reduction; the third failed to do so when used to achieve a 20 percent water reduction. (Author)

  • Corporate Authors:

    U.S. Army Waterways Experiment Station

    3909 Halls Ferry Road
    Vicksburg, MS  United States  39180-6199
  • Authors:
    • Saucier, K L
  • Publication Date: 1980-1

Media Info

  • Pagination: 23 p.

Subject/Index Terms

Filing Info

  • Accession Number: 00317639
  • Record Type: Publication
  • Source Agency: National Technical Information Service
  • Report/Paper Numbers: WES-TR-C-77-1-2 Tech Rpt.
  • Files: TRIS
  • Created Date: Jul 22 1980 12:00AM