CALCULATION OF CONVERSION FOR SPLITTING TENSILE STRENGTH ON 10 CM CONCRETE CORES

DIE UMRECHNUNG DER SPALTZUGFESTIGKEIT AM 10-CM-BETONBOHRKERN

The aim of the work was to determine guide values for converting the strength from a splitting tensile test for a 10 cm concrete core to the tensile strength in bending for a 60 cm or 70 cm beam, respectively. For this purpose an extensive test programme was arranged where cores were taken from halves of beams immediately after the bending test at an age of 56 days. By this method it was possible to make a prognosis of both types of strengths for the same sample. Both results obtained were therefore in a direct relation. From the large number of results it was possible to formulate a conversion expression for the above case. The relation which was determined is linear. (TRRL)

  • Corporate Authors:

    Transpress VEB Verlag fuer Verkehrswesen

    Franzoesische Strasse 13/14, Postfach 1235
    108 Berlin,   Germany 
  • Authors:
    • Moewes, J
  • Publication Date: 1978-5

Language

  • German

Media Info

  • Features: Figures; References; Tables;
  • Pagination: p. 167-170
  • Serial:
    • Strasse
    • Volume: 18
    • Issue Number: 5

Subject/Index Terms

Filing Info

  • Accession Number: 00315170
  • Record Type: Publication
  • Source Agency: Bundesanstalt für Straßenwesen (BASt)
  • Files: ITRD, TRIS
  • Created Date: Feb 6 1981 12:00AM