TEMPERATURE MEASUREMENTS IN CONCRETE STRUCTURES

TEMPERATURMAALINGER I BETONGKONSTRUKTIONER

The paper contains temperatures measured in concrete bridges during the hardening period. The bridges were insulated on the upper side with 50 mm mineral wool during the first 14 days of the hardening period. The measurements show that the selected insulation is sufficient to ensure that the difference between the temperature in the middle of the concrete and the surface is less than 20 deg C. In this case probably no cracks will arise from the temperature-gradients in the concrete. (TRRL)

  • Availability:
  • Corporate Authors:

    Nordiska Betongfoerbundet

    Fack
    10044 Stockholm 70,   Sweden 
  • Authors:
    • Jensen, B C
    • WESTERGAARD, J
  • Publication Date: 1979

Language

  • Danish

Media Info

  • Features: Figures; References;
  • Pagination: p. 25-27
  • Serial:
    • Nordisk Betong
    • Volume: 23
    • Issue Number: 4
    • Publisher: Nordiska Betongfoerbundet
    • ISSN: 002913070029-1307

Subject/Index Terms

Filing Info

  • Accession Number: 00310547
  • Record Type: Publication
  • Source Agency: Swedish National Road and Transport Research Institute (VTI)
  • Files: ITRD, TRIS