Time-dependent buckling testing of eccentrically loaded slender high-strength concrete panels

The results of nine full-scale high-strength concrete panels tested under eccentric sustained loads are presented in this paper. The panels were uniaxially loaded for up to 4 months. Four panels failed due to creep buckling at different times under sustained loads that are lower than their short-Term capacities. The other panels exhibited a long-Term stable behavior; they were then loaded to failure without the release of the existing sustained loads and exhibited a reduction in their residual strength due to creep. The study investigates the influences of aging of concrete, magnitude of the applied load, and the slenderness ratio. The experimental results are compared to theoretical predictions generated from a theoretical analysis that was previously developed by the authors. The formulation is based on the rheological generalized Maxwell model and it accounts for large deformation kinematics in the structural level. A close correlation is achieved between the experimental and theoretical results.

  • Record URL:
  • Availability:
  • Supplemental Notes:
    • Abstract reprinted with permission from the American Concrete Institute.
  • Authors:
    • Huang, Yue
    • Hamed, Ehab
    • Chang, Zhen-Tian
    • Foster, Stephen J
  • Publication Date: 2018-1

Language

  • English

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 01677175
  • Record Type: Publication
  • Files: TRIS
  • Created Date: Jul 6 2018 12:12PM