CARACTERIZACION FISICA DE PASTAS DE CEMENTOS HIBRIDOS A PARTIR DE CENIZA VOLANTE TIPO F Y SU EFECTO EN LAS PROPIEDADES ELECTROQUIMICAS DEL ACERO

Esta investigacion describe las propiedades fisicas y mecanicas de pastas de cementos hibridos, obtenidos a partir de ceniza volante tipo F (CV) + Cemento Portland Ordinario (CPO) (70% CV+30% CPO y 80 CV+20% CPO) hidratadas con disolucion alcalina (pH ~11.3). Incluye tambien el comportamiento electroquimico del acero de refuerzo embebido en tales pastas. Las tecnicas empleadas para la caracterizacion fisica fueron: resistividad electrica humeda (ρ), velocidad de pulso ultrasonico (VPU), absorcion capilar, resistencia a la compresion (f ´c). Las tecnicas electroquimicas para caracterizar al acero en estas pastas fueron: potencial de corrosion (Ecorr) y resistencia a la polarizacion lineal (Rpl). Los resultados indican que los cementos hibridos, proveen propiedades fisicas y mecanicas comparables con las alcanzadas con un Cemento Portland Ordinario 100%, incluso en el caso de la resistividad electrica los valores fueron superiores. Respecto al comportamiento electroquimico del acero de refuerzo, en los cementos hibridos en proporciones 70/30 (ceniza volante/Cemento Portland Ordinario en porcentaje), el nivel de corrosion fue menor respecto al Cemento Portland Ordinario (CPO). Abstract This research describes the physical and mechanical properties of hybrid cement pastes (fly ash type F + ordinary portland cement) with alkaline solution (pH ~11.3). It also includes the electrochemical behavior of reinforcing steel embedded in such pastes. The techniques used were: electrical resistivity (ρ), ultrasonic pulse velocity (VPU), percentage of total water absorption, capillarity, compressive strength (f´c), corrosion potential (Ecorr) and resistance to polarization Rp). The results indicate that hybrid cements provide physical and mechanical properties comparable with respect to ordinary portland cement. The electrical resistivity values were higher with this hybrid cement. With respect to the electrochemical behavior of the reinforcing steel, the corrosion level was lower in the 70/30 (fly ash / ordinary portland cement) compared to ordinary portland cement.

Language

  • Spanish

Media Info

  • Media Type: Web
  • Features: Bibliography; Figures; Tables;
  • Pagination: viii+47p
  • Serial:
    • Issue Number: 486

Subject/Index Terms

Filing Info

  • Accession Number: 01626985
  • Record Type: Publication
  • Source Agency: Instituto Mexicano del Transporte
  • Files: ITRD
  • Created Date: Feb 27 2017 9:37AM