An arc-light-based method for estimation of contact strip wear

A measured contact-loss ratio is used to estimate current-collection performance. There are two types of methods used to estimate the contact-loss ratio. One is to measure all the contact losses, including small ones; the other is to measure only contact losses that are greater than 5?ms in duration. The extent of wear of a contact strip caused by arc discharges varies as a function of the amount of electric charge. This fact makes it possible to manage the wear on a contact strip. This paper shows a calculation method for the amount of electric charge based on the output of a contact-loss measurement as well as the expected lifetime of the contact strip and the creation of a maintenance threshold level for of the contact strip.

Language

  • English

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 01599748
  • Record Type: Publication
  • Files: TRIS
  • Created Date: May 4 2016 9:00AM