ELEVENTH PROGRESS REPORT OF THE ROLLING-LOAD TESTS OF JOINT BARS
This report discusses the test program of rolling load tests of joint bars using 3-33 inch stroke rolling machines. The results of the tests of joint bars, which were heat treated and tempered are given. Hardness tests of the bars are included as well as the rolling load tests. Test results of 132 RE leadfree bars (oil quenched) averaged 573,100 cycles before failure which started at a rail end. Tests of 132 RE leadfree bars (water quenched) averaged 365,300 cycles. 4 bars failed, 2 from the top, 2 from the base.
-
Corporate Authors:
American Railway Engineering Association
59 East Van Buren Street
Chicago, IL United States 60605 -
Authors:
- Jensen, R S
- Publication Date: 1953
Media Info
-
Serial:
- AREA BULLETIN
- Volume: 54
- Publisher: American Railway Engineering Association
Subject/Index Terms
- TRT Terms: Dynamic loads; Failure; Fastenings; Rail (Railroads); Rail joints; Railroad tracks; Technology; Tie bars
- Geographic Terms: United States
- Old TRIS Terms: Rail failure
- Subject Areas: Materials; Railroads;
Filing Info
- Accession Number: 00039451
- Record Type: Publication
- Files: TRIS
- Created Date: Jul 8 1994 12:00AM