Development of a Traction Circuit for Battery-powered and AC-fed Dual Source EMU and Running Test Evaluation of the On-board Battery Performance

The authors have converted an existing AC electric multiple unit train (EMU) into a battery-powered and AC-fed dual source EMU (test train) to allow interoperable service between AC electrified lines and non-electrified lines. This paper describes the features and the test results of the developed traction circuit. Results of the on-board battery performance evaluation are also reported, as follows: 1) the running distance, without recharging, of the test train fed by the on-board lithium-ion battery (1382V-83kWh) was approx. 20-30 km, 2) the maximum temperature of the battery was 51.5℃ leaving a sufficient margin before the upper limit of 65℃, 3) the time required for quick charging increases when the battery is in low temperature conditions. The running test results demonstrate that the on-board battery performance is sufficient to permit interoperable services between AC electrified and non-electrified lines.

Language

  • English
  • Japanese

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 01570956
  • Record Type: Publication
  • Source Agency: Japan Science and Technology Agency (JST)
  • Files: TRIS, JSTAGE
  • Created Date: Jul 28 2015 3:51PM