CORROSION OF STEEL REINFORCEMENT IN POLYMER CONCRETE /IN RUSSIAN/

IN POLYMER CONCRETE WITH A FURFURAL-ACETONE MONOMER BASE AND A 5 TO 6 PH, REINFORCEMENT IS NOT SUBJECT TO CORRISION IN A DRY ATMOSPHERE. WHEN POLYMER REINFORCED CONCRETE SAMPLES ARE PRESERVED IN AN ACID ENVIRONMNET, ESPECIALLY IN REHEATED ACIDS, CORROSION OF THE REINFORCEMENT SHOWS A MARKED INCREASE. A THICKER PROTECTIVE LAYER SLOWS DOWN THE CORROSION PROCESS. WHEN POROUS AGGREGATES ARE USED, THEY MUST BE OF SMALL DIMENSIONS. POLYMER CONCRETE (FURFURAL- ACETONE, GRANITIC AGGREGATES, QUARTZ SAND) CURED IN HOT ACIDS, HAS A LOW CHEMICAL STRENGTH AND GIVES INSUFFICIENT PROTECTION TO THE REINFORCEMENT. /LCPC/RRL/

  • Supplemental Notes:
    • No 5, pp 6-8, 2 FIG, 2 TAB, 1 PHOT, 3 REF
  • Authors:
    • Berman, G M
    • Moshchanskii, N A
  • Publication Date: 1969-5

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00216591
  • Record Type: Publication
  • Source Agency: Road Research Laboratory /UK
  • Files: TRIS
  • Created Date: May 26 1971 12:00AM