ESSAIS TRIAXIAUX SUR ENROBES BITUMINEUX EN CHARGEMENT REPETE OU EN FLUAGE

L'AUTEUR PRESENTE UNE ETUDE DE L'ESSAI PROPREMENT DIT ET MET EN EVIDENCE L'INFLUENCE DES DIVERS PARAMETRES DE SOLLICITATION : DUREE D'APPLICATION DE LA CHARGE, TEMPERATURE, TEMPS DE REPOS, CONTRAINTE VERTICALE, CONTRAINTE LATERALE CONSTANTE OU SINUSOIDALE. PARMI LES RESULTATS LES PLUS INTERESSANTS OBTENUS ON PEUT CITER LE FAIT QUE : 1) CE SOIT LE TEMPS TOTAL DE CHARGEMENT QUI DETERMINE LES DEFORMATIONS PERMANENTES, INDEPENDAMMENT DE LA FREQUENCE DE CHARGEMENT ; 2) UNE CONTRAINTE LATERALE SINUSOIDALE N'APPORTE RIEN DE PLUS QUE LA CONTRAINTE LATERALE CONSTANTE ; 3) LES PERIODES DE REPOS N'ONT PAS D'EFFET ; 4) L'ON PEUT PASSER DE FACON SIMPLE D'ESSAIS DE FLUAGE STATIQUE A DES ESSAIS DE FLUAGE DYNAMIQUE ; 5) LE TAUX DE FLUAGE N'EST PAS CONSTANT EN COURS D'ESSAI. (VOIR FICHE GENERALE NUMERO 107043).

Language

  • French

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 01297717
  • Record Type: Publication
  • Source Agency: Institut Francais des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR)
  • Files: ITRD
  • Created Date: Nov 21 2010 6:28AM