TRAVAUX DE BETONNAGE SOUS CLIMATS CHAUDS

L'EXPERIENCE DE CHANTIERS DE CONSTRUCTION DE REVETEMENTS BETONNES SUR DEUX AEROPORTS A ABU-DHABI (EMIRATS ARABES UNIS) EST DECRITE. LES CONDITIONS CLIMATIQUES SONT CARACTERISEES PAR DES TEMPERATURES ELEVEES (7 A 52 DEGRES C SOUS ABRI), DE FORTES AMPLITUDES D'HYGROMETRIE (20 A 100 %) ET UNE TRES FAIBLE PLUVIOMETRIE. LA QUALITE DES GRANULATS ET DES CIMENTS LOCAUX A PERMIS D'OBTENIR DES RESISTANCES MECANIQUES ELEVEES. LA MISE EN OEUVRE S'EST EFFECTUEE DE NUIT ET LE PRINCIPAL SOUCI A ETE D'EVITER LA FISSURATION PRECOCE PAR RETRAIT HYDRAULIQUE AVANT PRISE. CECI A PU ETRE OBTENU GRACE A UNE STRICTE DISCIPLINE DE CHANTIER CONCERNANT PRINCIPALEMENT : - LE REFROIDISSEMENT DE L'EAU DE GACHAGE, - LE MALAXAGE DU BETON JUSQU'A COMPLETE HOMOGENEISATION, - L'EMPLOI DE PLASTIFIANT REDUCTEUR D'EAU ET UNE CONSISTANCE FERME DU BETON, - LA PROJECTION DE JETS DE BROUILLARD ENTRE LA LISSEUSE ET LE TRAIN DE FINITION ET D'APPLICATION PRECOCE DE PRODUIT DE CURE (UNE HEURE AU MAXIMUM APRES LA FABRICATION DU BETON), - TOILES DE JUTES HUMIDIFIEES PENDANT PLUSIEURS JOURS. (A).

Language

  • French

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 01278262
  • Record Type: Publication
  • Source Agency: Institut Francais des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR)
  • Files: ITRD
  • Created Date: Nov 20 2010 7:15PM