TORSION AND SHEAR TESTS ON PRESTRESSED BOX GIRDERS, 1963-64

DESTRUCTIVE TESTS ON TWO MODEL SINGLE-CELL PRESTRESSED BOX GIRDERS WITH CANTILEVERED TOP SLABS ARE DESCRIBED. THE GIRDERS WERE PRESTRESSED ON THE 'MONIERBAU' SYSTEM AND REINFORCED WITH STIRRUP AND MESH REINFORCEMENT. THREE CROSS-WEB DIAPHRAGMS WERE BUILT INTO THE GIRDERS IN ORDER TO DISTRIBUTE THE LOADS OVER THE GIRDER CROSS-SECTION. ONE GIRDER WAS CENTRALLY LOADED ALMOST TO FLEXURAL FAILURE, THEN ECCENTRICALLY LOADED UNTIL TORSIONAL FAILURE OCCURRED; THE OTHER WAS TESTED TO TORSIONAL FAILURE WITH A GREATER ECCENTRICITY OF LOADING. THE RESULTS ARE PRESENTED GRAPHICALLY AND ANALYSED. /RRL/

  • Supplemental Notes:
    • 41 Pp, Figs, PHOTS, 13 REF
  • Corporate Authors:

    Cement and Concrete Association

    52 Grosvenor Gardens
    London SW1W 0AQ,   England 
  • Authors:
    • LEONHARDT, F
    • WALTHER, R
  • Publication Date: 0

Subject/Index Terms

Filing Info

  • Accession Number: 00208762
  • Record Type: Publication
  • Source Agency: Road Research Laboratory /UK
  • Files: TRIS
  • Created Date: Oct 25 1971 12:00AM