COMPOSITE STEEL-DECK-REINFORCED CONCRETE SYSTEMS FAILING IN SHEAR-BOND

SHEAR-BOND MAY BE CLASSED AS A BRITTLE TYPE OF FAILURE AND IS CHARACTERIZED BY THE FORMATION OF AN APPROXIMATE DIAGONAL CRACK, RESULTING IN END-SLIP AND LOSS OF BOND BETWEEN THE STEEL DECK AND CONCRETE. THE ULTIMATE SHEAR-BOND CAPACITY OF STEEL-DECK-REINFORCED SYSTEMS IS A FUNCTION OF THE COMPRESSIVE STRENGTH OF CONCRETE, THE DEPTH AND WIDTH OF SLAB, THE THICKNESS OF STEEL DECK, THE SHEAR SPAN AND 2 CONSTANTS TO BE EVALUATED FROM EXPERIMENTAL TEST DATA. A PLUS OR MINUS 18% CORRELATION BETWEEN EXPERIMENTAL AND CALCULATED SHEAR-BOND STRESSES EXISTED. /AUTHOR/

  • Corporate Authors:

    International Association for Bridge and Structural Engineering

    ETH-Honggerberg, Wolfgang-Pauli-Strasse 15
    Zurich 8093,   Switzerland  CH-8093
  • Authors:
    • Schuster, R M
  • Publication Date: 1972-5

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00209731
  • Record Type: Publication
  • Files: TRIS
  • Created Date: Aug 7 1972 12:00AM