DISCUSSION OF VOID SPACING AS A BASIS FOR PRODUCING AIR- ENTRAINED CONCRETE

THE DISCUSSION CENTERS AROUND THE USE OF A SPACING FACTOR OF 0.01 IN. AS A SAFE LIMIT. BUREAU OF RECLAMATION TESTS INDICATE THAT A LIMIT LOWER THAN 0.01 IN. IS NECESSARY. THE AUTHOR'S CLOSURE CONTRASTS THE EXPERIMENTAL TECHNIQUES USED, AS REGARDS RATE OF COOLING AND DEGREE OF SATURATION. THE 0.01 IN. LIMIT WAS SET ON THE BASIS OF FIELD EXPOSURE CONDITIONS RATHER THAN THOSE OF ACCELERATED LABORATORY TESTS. /PCA/