Interlaboratory Study to Determine the Precision of the MIT Scan T2 for PCC Pavement Thickness

The MIT Scan T2 device has been implemented in Iowa as a new method for determining PCC pavement thickness compliance. The T2 device utilizes a magnetic pulse induction technology to measure the distance from a sensor to a metal target. The objective of this project was to conduct an interlaboratory study (ASTM C802) to determine the precision of the test. Fifteen MIT Scan T2 gauges and fifteen operators performed testing on three reference platforms and nine pavement locations of varying thicknesses. The testing was conducted on October 29, 2014 at two sites near Ames, Iowa. Usable data was obtained from every operator at all locations.

Language

  • English

Media Info

  • Media Type: Digital/other
  • Edition: Final Report
  • Features: Appendices; Figures; Maps; Photos; Tables;
  • Pagination: 18p

Subject/Index Terms

Filing Info

  • Accession Number: 01597304
  • Record Type: Publication
  • Report/Paper Numbers: MLR-14-01
  • Files: TRIS, ATRI, STATEDOT
  • Created Date: Apr 26 2016 8:55AM