<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Transport Research International Documentation (TRID)</title>
    <link>https://trid.trb.org/</link>
    <atom:link href="https://trid.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMCIgLz48L3BhcmFtcz48ZmlsdGVycz48ZmlsdGVyIGZpZWxkPSJpbmRleHRlcm1zIiB2YWx1ZT0iJnF1b3Q7U3RhY2sgZ2FzIGVtaXNzaW9ucyZxdW90OyIgb3JpZ2luYWxfdmFsdWU9IiZxdW90O1N0YWNrIGdhcyBlbWlzc2lvbnMmcXVvdDsiIC8%2BPC9maWx0ZXJzPjxyYW5nZXMgLz48c29ydHM%2BPHNvcnQgZmllbGQ9InB1Ymxpc2hlZCIgb3JkZXI9ImRlc2MiIC8%2BPC9zb3J0cz48cGVyc2lzdHM%2BPHBlcnNpc3QgbmFtZT0icmFuZ2V0eXBlIiB2YWx1ZT0icHVibGlzaGVkZGF0ZSIgLz48L3BlcnNpc3RzPjwvc2VhcmNoPg%3D%3D" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Transport Research International Documentation (TRID)</title>
      <url>https://trid.trb.org/Images/PageHeader-wTitle.jpg</url>
      <link>https://trid.trb.org/</link>
    </image>
    <item>
      <title>EVALUATION OF STACK EMISSIONS FROM HMA FACILITY OPERATIONS</title>
      <link>https://trid.trb.org/View/459580</link>
      <description><![CDATA[This report provides data to aid the National Asphalt Pavement Association members in evaluating and responding to: emissions inventory surveys; emission standards as they are proposed; any proposed air operating permits for individual facilities.]]></description>
      <pubDate>Mon, 24 Jun 1996 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/459580</guid>
    </item>
    <item>
      <title>DEALING WITH TITLE V OPERATING PERMITS: THE "SYNTHETIC MINOR" ALTERNATIVE</title>
      <link>https://trid.trb.org/View/459581</link>
      <description><![CDATA[The purpose of this document is to aid state agencies and owner/operators of Hot Mix Asphalt (HMA) facilities in performing the required calculations for determining a plant's status under Title V of the Clean Air Act Amendments 1990 guidelines. In fact, most HMA facilities can qualify as synthetic minor (conditional major) sources and defer or avoid having to apply for a Title V air operating permit.]]></description>
      <pubDate>Mon, 24 Jun 1996 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/459581</guid>
    </item>
    <item>
      <title>MARINE BOILERS FOR LOW HORSEPOWER SHIPS</title>
      <link>https://trid.trb.org/View/143432</link>
      <description><![CDATA[The size and evaporation rate of marine boilers manufactured between 1960 and 1974 steadily increased to such an extent that, for a 300,00-dwt tanker, the evaporation rate was in the order of 105,000 kg/h for a single-boiler installation operating at 32,000 shp.  The present trend towards smaller ships, with consequent reductions in horsepower, has led to evaporation rates in the range of 17,500 kg/h to 33,000 kg/h for a 10,000 shp and a 20,000 shp twin-boiler installation respectively.  Some of the design and operating features of the larger boilers, i.e. welded-wall construction, single casing and tangential firing, can be retained for the smaller boilers.  This paper discusses the design and operating features of the smaller boilers including reheat designed for low horsepowers and partial load performance of both reheat and non-reheat designs.  Stack Gas analysis and fuel analysis have been included to show present day fuel trends and partial load stack conditions.  Order from BSRA as No. 51,969.]]></description>
      <pubDate>Wed, 27 Feb 1980 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/143432</guid>
    </item>
    <item>
      <title>IMPROVED MARINE BOILED RELIABILITY--PHASE II</title>
      <link>https://trid.trb.org/View/143023</link>
      <description><![CDATA[Presented in this paper are the results of a Maritime Administration-funded shipboard and laboratory test program the second phase of a project to identify and investigate design and operational parameters which have a significant impact on the performance, availability, and reliability of oil-fired marine boilers.  The research test results and engineering analyses are discussed as they pertain to the following task areas which affect marine boiler reliability: superheater corrosion rates; economizer corrosion rates; steam-side distribution in superheaters; stack gas analysis; thermocouple modernization and shipboard use; and boiler water and feedwater quality maintenance.  Recommendations based upon both phases of the program are presented which will enable the boiler purchaser or designer to specify certain materials, design features, and operating guidelines which should assist in establishing a predetermined level of boiler reliability for specific anticipated operating modes and environment.]]></description>
      <pubDate>Mon, 11 Feb 1980 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/143023</guid>
    </item>
    <item>
      <title>HOT FLOW TESTING OF MULTIPLE NOZZLE EXHAUST EDUCTOR SYSTEMS</title>
      <link>https://trid.trb.org/View/82856</link>
      <description><![CDATA[Hot flow model tests of multiple nozzle exhaust eductor systems were conducted to evaluate effects of exhaust temperature on eductor performance. A one-dimensional analysis of a simple eductor system based on conservation of momentum for an incompressible gas was used in determining the non-dimensional parameters governing the flow phenomenon. Eductor performance is defined in terms of these parameters. An experimental correlation of these parameters which was previously developed and used to correlate cold flow data was found to be effective in correlating both cold and hot flow data for eductor systems. Temperature data was obtained for the mixing stack wall and the exhaust flow at the mixing stack exit plane. (Author)]]></description>
      <pubDate>Sat, 26 May 1979 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/82856</guid>
    </item>
    <item>
      <title>U.S. COAST GUARD POLLUTION ABATEMENT PROGRAM: CUTTER ESTIMATED EXHAUST EMISSIONS</title>
      <link>https://trid.trb.org/View/57681</link>
      <description><![CDATA[The gaseous and particulate emissions of the Coast Guard cutter fleet are estimated by using measured emission factors and derived operational duty cycles. These data are compared to previous estimates by using emission factors found in the literature and the EPA estimates of total national vessel emissions and the total national emissions from all transportation sources. The U.S. Coast Guard fleet emissions for all categories of pollutants are less than 1% of the national transportation totals. (Author)]]></description>
      <pubDate>Mon, 30 Jan 1978 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/57681</guid>
    </item>
    <item>
      <title>STACK DESIGN TECHNOLOGY FOR NAVAL AND MERCHANT SHIPS</title>
      <link>https://trid.trb.org/View/55919</link>
      <description><![CDATA[This paper discusses design techniques for surface ship stack casings and exhaust duct terminals.  The discussion treats both naval combatant and auxiliary vessel stack designs, as well as commercial stack configurations.  The traditional engineering problems unique to stack design are described.  These include naval architectural problems associated with topside arrangements and superstructure design as well as safety and esthetic considerations associated with entrainment of the smoke plume in downwash passing over ship's decks.  The experimental data base for the design practices used by the U.S. Navy is presented and discussed.  Examples of unique contributions to the state-of-the-art are presented.  Analytical theory and procedures are descriged in detail.  These include design guidance for selecting the height, shape, location of the stack, and techniques or estimating the downward plume gas temperatures and trajectories.]]></description>
      <pubDate>Wed, 23 Nov 1977 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/55919</guid>
    </item>
    <item>
      <title>IMPROVED MARINE BOILER RELIABILITY. PHASE II. VOLUME IV. STACK GAS ANALYSIS</title>
      <link>https://trid.trb.org/View/50978</link>
      <description><![CDATA[This report presents the results of shipboard testing of a modern marine boiler for stack gas constituents related to corrosion and air quality. Special instrumentation and gas sampling equipment was used to obtain stack gas concentrations of oxygen, carbon monoxide, sulfur dioxide, sulfur trioxide, water vapor, and nitrogen oxides. Tests were performed at six boiler load ratings ranging from 11% to 110% over a wide range of excess air levels. Results obtained serve to characterize the conversion of SO2 to SO3 for the test boiler and permit the calculation of sulfuric acid dew point, demonstrating the dependence of dew point temperature on excess air level and boiler load. Nitrogen oxides were recorded over the complete test range (including an in-port condition) to establish a relationship between stack emissions, boiler load, and excess air for the boiler under test.]]></description>
      <pubDate>Wed, 31 Aug 1977 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/50978</guid>
    </item>
    <item>
      <title>SHIPBOARD HEAT RECOVERY PROGRAM FOR U.S. MERCHANT SHIPS</title>
      <link>https://trid.trb.org/View/50986</link>
      <description><![CDATA[The feasibility of recovering waste energy aboard U.S. Flag ships has been investigated. Utilizing a combination of heat sources, about 300 kw of power can be recovered from a typical 24000 hp steam ship. Small inland waterways diesel powered ships (approximately 2800 SHP) offer a promising opportunity to recover waste stack heat. Typical hardware layouts are presented based on the use of Freons as the Rankine Cycle power fluid.]]></description>
      <pubDate>Wed, 31 Aug 1977 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/50986</guid>
    </item>
    <item>
      <title>AIR FLOW AND STACK GAS DISPERSION EXPERIMENTS FOR A 270-FT U.S. COAST GUARD MEDIUM ENDURANCE CUTTER (WMEC) REPRESENTED BY MODEL 5349</title>
      <link>https://trid.trb.org/View/62705</link>
      <description><![CDATA[A project was established at the David W. Taylor Naval Ship R and D Center (DTNSRDC) to assist the U.S. Coast Guard in the evaluation of a design for a 270-ft Medium Endurance Cutter (WMEC).  This report documents the Air Flow and Stack Gas Dispersion Experiments requested.  Results show improved stack gas flow when the uptakes are raised approximately 21 inches from the original location.  (Author)]]></description>
      <pubDate>Tue, 31 May 1977 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/62705</guid>
    </item>
    <item>
      <title>MARITIME ADMINISTRATION CHEMICAL WASTE INCINERATOR SHIP PROJECT. VOLUME I.</title>
      <link>https://trid.trb.org/View/44200</link>
      <description><![CDATA[The report describes the monitoring activities undertaken to evaluate ocean incineration as a disposal method.  It also includes comments presented by different organizations and concerned firms regarding the suitability of this method of disposal.]]></description>
      <pubDate>Tue, 26 Oct 1976 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/44200</guid>
    </item>
    <item>
      <title>ROTARY REGENERATIVE AIR PREHEATERS FOR MARINE BOILERS</title>
      <link>https://trid.trb.org/View/33864</link>
      <description><![CDATA[Regenerative air preheaters possess unique characteristics which contribute to the reduction of funnel stack losses whilst permitting continuous operation over long periods. The paper includes the experience to date, a technical description, the financial savings based on an 11 per cent saving in fuel, the design developments; and concludes by describing some of the other applications which range from the largest power station boiler to chemical plants and furnaces.]]></description>
      <pubDate>Wed, 21 Apr 1976 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/33864</guid>
    </item>
    <item>
      <title>STACK GAS EMISSIONS FROM OCEANGOING SHIPS: REGULATIONS, SIGNIFICANCE, AND CONTROL METHODS.</title>
      <link>https://trid.trb.org/View/31292</link>
      <description><![CDATA[Regulations applicable throughout the U.S. for ship stack gas emissions and comparable shoreside emissions were reviewed.  No Federal regulations for ship stack gas emissions exist at this time.  However, many state and local regulations are being imposed on the shipping industry.  The significance of the stack gas problem was examined by reviewing the types of ships and fuel used, the types of emissions of concern, the overall contribution of pollutants by oceangoing ships, and the contribution of vessels in a port area.  Control methods for the various air pollutants, including automatic combustion control systems, are discussed.]]></description>
      <pubDate>Thu, 29 May 1975 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/31292</guid>
    </item>
    <item>
      <title>STACK GAS EMISSIONS FROM OCEANGOING SHIPS: A DIFFUSION STUDY FOR THE PORT OF GALVESTON</title>
      <link>https://trid.trb.org/View/31294</link>
      <description><![CDATA[A mathematical diffusion study was performed for the port of Galveston to determine the effect of ship stack gas emissions on ambient air quality.  The Gaussian distribution equation, the Holland stack rise equation, the EPA Air Quality Display Model (modified), and input data from actual and theoretical conditions were used in the study.  The results of the study are isopleths for particulate, carbon monoxide, sulfur dioxide, Nitrogen Oxides (NOx), and hydrocaborn emissions.  Additionally, data are provided on the maximum ground level concentrations of each of the above pollutants.  A comparison of these data with Federal Ambient Air Quality Standards shows that sulfur dioxide emissions from the use of 2.5% sulfur in the fuel slightly exceed the secondary standard.]]></description>
      <pubDate>Thu, 29 May 1975 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/31294</guid>
    </item>
    <item>
      <title>A STUDY OF STACK EMISSIONS FROM COAST GUARD CUTTERS</title>
      <link>https://trid.trb.org/View/14389</link>
      <description><![CDATA[The gaseous and particulate emissions from 14 cutters and boats in the First Coast Guard District have been measured under typical operating conditions. These measurements were performed on 57 diesel engines and boilers configured as main propulsion units, ship-service generators and hotel-service boilers. The diesel engines varied in size from two-cylinder, naturally aspirated, 35 h.p. units to 3600 h.p. turbo-charged units. The gaseous emission concentrations measured were carbon monoxide, carbon dioxide, total hydrocarbons, and oxides of nitrogen. Particulate emission rates by gravimetric technique as well as smoke levels were also documented. These measured concentrations were reduced to mass emission notes by appropriate computer programs. (Author)]]></description>
      <pubDate>Mon, 25 Mar 1974 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/14389</guid>
    </item>
  </channel>
</rss>