<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Transport Research International Documentation (TRID)</title>
    <link>https://trid.trb.org/</link>
    <atom:link href="https://trid.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMCIgLz48L3BhcmFtcz48ZmlsdGVycz48ZmlsdGVyIGZpZWxkPSJpbmRleHRlcm1zIiB2YWx1ZT0iJnF1b3Q7SW5kdWN0aXZlIGludGVyZmVyZW5jZSZxdW90OyIgb3JpZ2luYWxfdmFsdWU9IiZxdW90O0luZHVjdGl2ZSBpbnRlcmZlcmVuY2UmcXVvdDsiIC8%2BPC9maWx0ZXJzPjxyYW5nZXMgLz48c29ydHM%2BPHNvcnQgZmllbGQ9InB1Ymxpc2hlZCIgb3JkZXI9ImRlc2MiIC8%2BPC9zb3J0cz48cGVyc2lzdHM%2BPHBlcnNpc3QgbmFtZT0icmFuZ2V0eXBlIiB2YWx1ZT0icHVibGlzaGVkZGF0ZSIgLz48L3BlcnNpc3RzPjwvc2VhcmNoPg%3D%3D" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Transport Research International Documentation (TRID)</title>
      <url>https://trid.trb.org/Images/PageHeader-wTitle.jpg</url>
      <link>https://trid.trb.org/</link>
    </image>
    <item>
      <title>Recommended Practices for Rail Transit Intra-System Electromagnetic Compatibility of Vehicular Electrical Power and Track Circuit Signalling Subsystems; Volume I: Inductive Recommended Practices</title>
      <link>https://trid.trb.org/View/1493767</link>
      <description><![CDATA[Methods for detecting and quantifying the levels of inductive electromagnetic interference produced by solid state rapid transit propulsion equipment and the susceptibility of audio-frequency signalling systems to these emissions are presented. These methods include procedures for taking measurements in the field, in the laboratory and on track circuits. As background, the mechanisms of inductive and conductive electromagnetic interference are described, as are audio-frequency track circuits and dc chopper control. Recording and documentation procedures for applying these recommended practices are provided. Appendix A contains definitions of terms and systems of units. Appendix B contains sample outputs of tests using inductive recommended practices.]]></description>
      <pubDate>Tue, 23 Jan 2018 15:19:30 GMT</pubDate>
      <guid>https://trid.trb.org/View/1493767</guid>
    </item>
    <item>
      <title>Circuit Simulator for Prediction of Electromagnetic Induction up to Data Transmission Frequency in Railway Environment</title>
      <link>https://trid.trb.org/View/1440436</link>
      <description><![CDATA[In the traction circuit, the feeding current causes inductive interference with metallic telecommunication lines. It is therefore necessary to reduce the influence of electromagnetic induction by the design using results of computer simulation. A circuit analysis program for the railway environment named ABTAC is available, although the calculation method is applicable only to low frequencies and conductors present in a structure are ignored. Nowadays, high speed data transmission systems by means of metallic telecommunication lines such as xDSL (Digital Subscriber Line) are being introduced and the frequencies used in these systems are higher than audio frequencies. Considering the electromagnetic screening effect of conductors in structures makes the prediction of electromagnetic induction more accurate. This study describes the development of a new circuit simulator. This tool will make it possible to take into account conductors in the structure and calculate voltage and current up to the data transmission frequency.]]></description>
      <pubDate>Tue, 27 Dec 2016 08:42:55 GMT</pubDate>
      <guid>https://trid.trb.org/View/1440436</guid>
    </item>
    <item>
      <title>Measurement and Analysis of Interference Affecting Inductive Wheel Sensors</title>
      <link>https://trid.trb.org/View/902333</link>
      <description><![CDATA[This report describes efforts by the Frauscher Company (Frauscher GmbH) to make it possible to record events affecting railway inductive wheel sensors on-the-spot, without causing any feedback to those sensors. The report then discusses the event recordings with extensive laboratory analysis of the measurements.]]></description>
      <pubDate>Tue, 20 Oct 2009 07:40:33 GMT</pubDate>
      <guid>https://trid.trb.org/View/902333</guid>
    </item>
    <item>
      <title>Neural Network Incident Detection On Arterials Using Fusion of Simulated Probe Vehicle And Loop Detector Data</title>
      <link>https://trid.trb.org/View/771935</link>
      <description><![CDATA[This paper describes the development of neural network models for Automatic Incident Detection (AID) on arterials, using simulated data derived from Inductive Loop Detectors (ILDs) and probe vehicles. This study extends previous research by comparing the performance of various neural network architectures for data fusion and by providing a comparison of model performance for various probe vehicle penetration rates and detector configurations. Data from 108 incidents was collected from ILDs and probe vehicles at two locations on a previously validated network for two detector configurations. Configuration 1 was similar to a freeway link, while Configuration 2 conformed to the standard configuration on road networks. The best performance obtained for Configuration 1 was a Detection Rate (DR) of 59% for a False Alarm Rate (FAR) of 0.5%, for a probe vehicle penetration rate of 20%. The best performance obtained for Configuration 2 was a DR of 86% for a FAR of 0.36% for a probe vehicle penetration rate of 20%. Satisfactory performance can also be obtained using ILD data alone (DR = 86% for FAR = 0.41%). Inclusion of speed data further improves performance (DR = 90% for FAR = 0.5%) and its use when available is highly recommended. This research demonstrates the feasibility of developing a neural network model for detection of incidents on arterials using loop and probe vehicle data. Options for further study are also presented.]]></description>
      <pubDate>Tue, 31 Jan 2006 09:56:21 GMT</pubDate>
      <guid>https://trid.trb.org/View/771935</guid>
    </item>
    <item>
      <title>INDUCTIVE INTERFERENCE IN RAPID TRANSIT SIGNALING SYSTEMS. VOLUME III: DATA AND TEST RESULTS</title>
      <link>https://trid.trb.org/View/279571</link>
      <description><![CDATA[This report presents comparative inductive interference data obtained from four U.S. rapid transit systems employing chopper propulsion control, as part of the Rail Transit Electromagnetic Interference/Electromagnetic Compatibility program conducted by the Transportation Systems Center in Cambridge, Massachusetts.  Chopper propulsion control is standard at three of the systems:  Bay Area Rapid Transit District (BART); Metropolitan Atlanta Rapid Transit Authority (MARTA); and Greater Cleveland Regional Transit Authority (GCRTA).  The fourth system, New York City Transit Authority (NYCTA), conducted operational tests of a prototype chopper propulsion system installed in a married pair of R-46 cars.  The four propulsion systems were designed and manufactured by four different suppliers.  The theory of inductive interference generation in rapid transit signaling systems and discussion of the mechanisms involved, has been presented in an earlier report in this series: Inductive Interference in Rapid Transit Signaling Systems, Volume I:  Theory and Background (NTIS Order Number PB 87-114427/AS, Price A03).  That report provides the basis for analyzing the supplementary data presented here. Suggested test procedures for observing, recording and analyzing inductive interference signals have been presented in a second report:  Inductive Interference in Rapid Transit Signaling, Volume II:  Suggested Test Procedures, which has not been entered into the NTIS system at this time.]]></description>
      <pubDate>Thu, 31 May 2001 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/279571</guid>
    </item>
    <item>
      <title>TRANSIENT AC INDUCTION ENVIRONMENTS FOR SIGNAL SYSTEMS</title>
      <link>https://trid.trb.org/View/675478</link>
      <description><![CDATA[Transient induction events may occur anywhere an AC power distribution lines shares right of way with the line of road. Usually originating with a lightning strike, the event injects significant AC current into the earth, possibly damaging signal equipment up to several miles.  The objective of this paper is to develop a transient induction criteria current waveform to be used in qualifying equipment and terminal protection devices.  A numerical solution of the multi conductor transmission line equations of electromagnetics is used to simulate an actual induction event that occurred near Tiffin, Ohio.]]></description>
      <pubDate>Wed, 28 Feb 2001 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/675478</guid>
    </item>
    <item>
      <title>RADIO BASED CONTROL TECHNOLOGY FOR TRANSIT APPLICATIONS "THE NEXT GENERATION"</title>
      <link>https://trid.trb.org/View/486795</link>
      <description><![CDATA[Alcatel's SELTRAC, communications based, moving block, train control concepts have been proven in safe, reliable revenue service on hundreds of miles of mainline railroad, high speed rail and transit systems, world-wide, for over 25 years.  We have continued to set the standard that has driven market demand for the features and benefits inherent in communications based train control.  A key characteristic of SELTRAC, as well as any communications based system, is a highly secure continuous, cyclic two way communications link between wayside and on-board control units.  Alcatel supports two types of train-to-wayside (TWC) communication links; the inductive loop and data radio.]]></description>
      <pubDate>Wed, 24 Jun 1998 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/486795</guid>
    </item>
    <item>
      <title>RAILROAD ELECTROMAGNETIC COMPATIBILITY: ENVIRONMENTAL TESTS AND COUPLING MEASUREMENTS</title>
      <link>https://trid.trb.org/View/177686</link>
      <description><![CDATA[Measurements were conducted at the Electromagnetic Compatibility Test Facility (EMCTF) at Pueblo, Colorado and documented for relevant characteristics of the environment, such as earth resistivity, resistance to remote earth (resistance to ground) of installed grounds, and the dc resistance of the cables that will be used for component testing. Measurements were conducted and documented for the voltage coupled to, i.e., induced into, representative cable conductors and between conductor pairs due to the voltage and current in the catenary. The applicability of analytical coupling models for calculating coupling between the catenary and the parallel communication and signal cables at the EMCTF was investigated.]]></description>
      <pubDate>Thu, 31 Mar 1983 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/177686</guid>
    </item>
    <item>
      <title>SIMULATION STUDIES OF AN ELECTRICAL INTERFERENCE PROBLEM AFFECTING MASS TRANSIT CIVIL ENGINEERING DESIGN</title>
      <link>https://trid.trb.org/View/160469</link>
      <description><![CDATA[Part I of the Paper gives a brief description of an automatic train protection (ATP) system for a mass transit railway, and indicates some problems that may arise because of inductive interference caused by the presence of reinforcing steel in the structures supporting the track. Part II deals with two months of study capable of yielding quantitative estimates of the interference effects in a reliable and systematic manner.  In the first method a full-scale simulated track system was built and, based on suitable instrumentation, the physical parameters as well as the relationships governing the inductive interference were determined.  The second method relies on establishing a mathematical model that invokes basic electromagnetic field theory and transmission line theory to arrive at a generalised solution.  The results obtained with both methods are presented and compared.]]></description>
      <pubDate>Sat, 11 Dec 1982 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/160469</guid>
    </item>
    <item>
      <title>EVALUATION OF SIGNAL/CONTROL SYSTEM EQUIPMENT AND TECHNOLOGY. TASK 4: ELECTRICAL NOISE DISTURBANCE</title>
      <link>https://trid.trb.org/View/162285</link>
      <description><![CDATA[This report defines electromagnetic interference (EMI) generated by wayside and vehicle-mounted equipment associated with railroad electrification. The report describes the adverse effects of EMI upon existing and potentially applicable signal/control systems. Functional requirements for EMI control are defined and recommendations are made for follow-on testing activity. The problems of vandalism are also considered.]]></description>
      <pubDate>Wed, 30 Dec 1981 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/162285</guid>
    </item>
    <item>
      <title>CALCULATION AND MEASUREMENT OF ELECTROMAGNETIC INFLUENCE ON TELECOMMUNICATION CABLES IN SUBWAY SYSTEMS BY POWER ELECTRONIC CIRCUITS</title>
      <link>https://trid.trb.org/View/79485</link>
      <description><![CDATA[For the subway in Vienna/Austria electrical drives for air flow control are considered whose speed is controlled by power electronic circuits.  The electric power line feeding the power electric circuits is mounted in parallel with the subway telecommunication cables over a length of close to six-hundred meters.  The current pulses -- caused by the power electronic control -- in the electric power line lead to induced voltages in the telecommunication cables.  This paper provides a derivation of equations to calculate the induced voltages.  A Fourier analysis of the current in the electrical power lines is performed.  The difficult problem of calculating the induced voltages in the telecommunication cables is solved by the conform mapping.  The real geometric configuration concerning magnetic field calculation.  In this configuration, by different mathematical operations, the induced voltages can be calculated.  Good comparison is found between calculation and measurement of induced (EMI) voltages.]]></description>
      <pubDate>Sat, 31 Oct 1981 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/79485</guid>
    </item>
    <item>
      <title>INTERFERENCES IN TELEPHONE CIRCUITS DUE TO THYRISTOR CONTROLLED D.C. TRACTION</title>
      <link>https://trid.trb.org/View/79486</link>
      <description><![CDATA[For efficient control of motors in the case of d.c. traction, a thyristor chopper is used.  Prior to introduction of thyristor chopper control in the metropolitan railway system extensive measurements were made in three cities of Fed. Rep. of Germany.  After a brief review of chopper control this paper deals with the inductive interference on telephone cables.  In general it can be established that the interference in telephone cables is mainly due to the current harmonics from the rectifier station.  Furthermore, as far as the induced voltage is concerned it makes practically no difference which type of control is being used, as long as the d.c. traction power is the same.]]></description>
      <pubDate>Sat, 31 Oct 1981 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/79486</guid>
    </item>
    <item>
      <title>CHOPPERS AFFECT OPERATION OF AF TRACK CIRCUITS</title>
      <link>https://trid.trb.org/View/154930</link>
      <description><![CDATA[Interference has been observed on US metros between the latest chopper-controlled trains and coded track circuits used for train detection as well as cab signals and ATO. The most dominant interference mechanism is inductive coupling between equipment carried on the car and the loop formed by the rails and axles under the car.  Currents induced in this loop can result in transient "track clear" indications as a powered car passes over the impedance bond separating adjacent track circuits.  A joint government-industry working group is developing ways of quantifying and controlling the problem.]]></description>
      <pubDate>Wed, 16 Sep 1981 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/154930</guid>
    </item>
    <item>
      <title>ELECTROMAGNETIC COMPATIBILITY TEST FACILITY FOR SIGNAL AND COMMUNICATION SYSTEMS</title>
      <link>https://trid.trb.org/View/174824</link>
      <description><![CDATA[The EMC Test Facility has been developed for a 3-mile segment of the 14-mile electrified Railroad Test Track at the Transportation Test Center at Pueblo, CO.  EMC has become more important as the usage and sophistication of electrical and electronic equipment has increased, now involving higher speed circuitry, broader bandwidths and greater utilization of all available frequencies. Electrification represents a major challenge to satisfactory operation of electronic systems that may be located along the right-of-way.  The Test Facility will include track circuits, buried cables, a typical open pole line and other components of a U.S. railroads wayside signal and communications system.]]></description>
      <pubDate>Wed, 16 Sep 1981 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/174824</guid>
    </item>
    <item>
      <title>INDUCTIVE INTERFERENCE ASPECTS OF THE DECISION TO ELECTRIFY</title>
      <link>https://trid.trb.org/View/174837</link>
      <description><![CDATA[The decision to electrify requires the evaluation of many technical and financial factors.  One of these is inductive interference.  There are three major aspects to inductive interference, which must be fully integrated with any electrification plans: safety to personnel, damage to equipment and incorrect data transmission.  This paper treats the problem of inductive interference under the headings: Electrostatic and electromagnetic induction; voltage limitations and industry guidelines; power supply systems; shielding; protection devices; application of inductive coordination.]]></description>
      <pubDate>Sat, 15 Aug 1981 00:00:00 GMT</pubDate>
      <guid>https://trid.trb.org/View/174837</guid>
    </item>