<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Transport Research International Documentation (TRID)</title>
    <link>https://trid.trb.org/</link>
    <atom:link href="https://trid.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMCIgLz48L3BhcmFtcz48ZmlsdGVycz48ZmlsdGVyIGZpZWxkPSJpbmRleHRlcm1zIiB2YWx1ZT0iJnF1b3Q7R2FsdmFuaXppbmcmcXVvdDsiIG9yaWdpbmFsX3ZhbHVlPSImcXVvdDtHYWx2YW5pemluZyZxdW90OyIgLz48L2ZpbHRlcnM%2BPHJhbmdlcyAvPjxzb3J0cz48c29ydCBmaWVsZD0icHVibGlzaGVkIiBvcmRlcj0iZGVzYyIgLz48L3NvcnRzPjxwZXJzaXN0cz48cGVyc2lzdCBuYW1lPSJyYW5nZXR5cGUiIHZhbHVlPSJwdWJsaXNoZWRkYXRlIiAvPjwvcGVyc2lzdHM%2BPC9zZWFyY2g%2B" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Transport Research International Documentation (TRID)</title>
      <url>https://trid.trb.org/Images/PageHeader-wTitle.jpg</url>
      <link>https://trid.trb.org/</link>
    </image>
    <item>
      <title>Hot-Dip Galvanizing: Bibliography</title>
      <link>https://trid.trb.org/View/2560859</link>
      <description><![CDATA[This publications contains a bibliography on hot-dip galvanizing as related to highway structures. The bibliography contains 64 citations.]]></description>
      <pubDate>Sat, 02 Aug 2025 11:40:32 GMT</pubDate>
      <guid>https://trid.trb.org/View/2560859</guid>
    </item>
    <item>
      <title>Study of the Growth Forecast of Zinc Whisker in the Market</title>
      <link>https://trid.trb.org/View/2387105</link>
      <description><![CDATA[The test conditions under which whiskers generated from galvanized steel sheets were investigated. Then, it was found that whiskers are generated when a temperature cycle that satisfies certain conditions is given. Based on the results, the authors estimated the correlation between heat stress and market stress in the test, and devised a method to determine an appropriate test period from the market temperature data.]]></description>
      <pubDate>Thu, 11 Jul 2024 13:53:12 GMT</pubDate>
      <guid>https://trid.trb.org/View/2387105</guid>
    </item>
    <item>
      <title>Hot-Dip Galvanizing Specification S8.3—2022</title>
      <link>https://trid.trb.org/View/2213675</link>
      <description><![CDATA[Developed by the American Association of State Highway and Transportation Officials (AASHTO)–National Steel Bridge Alliance (NSBA) Steel Bridge Collaboration, this specification presents information and practices for owners, designers, and fabricators for specifying hot-dip galvanizing of steel bridges and other highway structures, which provides a durable protection from corrosion.   The specification includes best practices for design and fabrication, as well as information on material properties of hot-dip galvanizing, types of materials suitable for hot-dip galvanizing, welding considerations and procedures, venting and draining, and distortion control.   The specification also presents information related to other zinc coating processes, including mechanical galvanizing, electroplating, and metalizing.]]></description>
      <pubDate>Thu, 20 Jul 2023 17:13:35 GMT</pubDate>
      <guid>https://trid.trb.org/View/2213675</guid>
    </item>
    <item>
      <title>Evaluation of Galvanized and Painted Galvanized Steel Piling</title>
      <link>https://trid.trb.org/View/2078725</link>
      <description><![CDATA[This project investigated the long-term protection of steel piles with galvanized and painted galvanized coatings using a corrosion chamber to accelerate corrosion effects in the laboratory. Further investigation was completed through observation of painted galvanized piles installed in the field at a newly constructed bridge in Buchanan County, Iowa. The primary objective of this research was to evaluate the effectiveness of galvanized and painted galvanized piles in extending bridge service life in a cost-effective manner. An economic evaluation was conducted comparing the use of a larger H-pile section, a galvanized coating, and a painted galvanized coating to protect the piles against corrosion. One solution to achieve a 100-yr design life is to increase the section size of the pile to allow for section loss without compromising the required pile capacity While the cost to increase the pile size was determined to be less than the premium for galvanizing or galvanizing and painting the piles for the bridge in this study, a cost-benefit evaluation for each protection measure is suggested knowing that costs can vary widely depending on specific project requirements, location, market prices, etc. This is an interim report, and the research team plans to continue to collect additional annual data from the Buffalo Creek Bridge in Buchanan County for future analysis.]]></description>
      <pubDate>Tue, 24 Jan 2023 09:30:20 GMT</pubDate>
      <guid>https://trid.trb.org/View/2078725</guid>
    </item>
    <item>
      <title>Longer Service Life Bridge Coatings</title>
      <link>https://trid.trb.org/View/2047375</link>
      <description><![CDATA[The Kentucky Transportation Cabinet (KYTC) has maintenance oversight responsibilities for approximately 1,100 steel bridges; it also helps local governments and other entities with maintenance painting on other steel bridges. Because maintaining steel bridges is costly, Cabinet officials asked Kentucky Transportation Center (KTC) researchers to identify materials and methods that will prolong their service lives. Steel bridges are uniquely vulnerable to deterioration resulting from exposure to atmospheric conditions (e.g. moisture, ultraviolet rays) and chlorides, the latter due to the application of deicing materials. This study examines two strategies for extending service lives. First, it appraises a novel method of hot dip galvanization (HDG) and metallizing girders. Rather than dipping an entire girder in molten zinc at once, steel plates are immersed and then welded to form girders. In testing, all pieces that were coated using the method were adequately galvanized and metallized, thus establishing adequate protection against corrosion. The process can likely be scaled up and applied to larger steel pieces and girders. Next, researchers investigated whether carrying out an additional abrasive blast cleaning following power washing can reduce chloride levels. A second blast cleaning did not significantly lower chloride levels, and even led to slight increases, which may be the product of unreliable field testing or the use of recycled steel grit abrasive. Other methods of reducing chlorides should accordingly be investigated (e.g., specialized coating systems, high-performance coating systems).]]></description>
      <pubDate>Mon, 28 Nov 2022 10:56:48 GMT</pubDate>
      <guid>https://trid.trb.org/View/2047375</guid>
    </item>
    <item>
      <title>Advancements in Galvanic Protection for Marine Structures</title>
      <link>https://trid.trb.org/View/2023461</link>
      <description><![CDATA[Concrete structures exposed to a marine environment can experience high maintenance costs and reduced service life due to corrosion. This is particularly true for concrete reinforced piles in seawater (or brackish water) where an individual concrete pile can have a variety of exposure conditions, including airborne chlorides, periodic wetting by splashing, regular wetting by tidal activity, and fully submerged. Galvanic jacketing systems have been successfully employed to address active corrosion on concrete piles in all exposure conditions. There are different variations of galvanic systems that incorporate zinc-based embedded anodes, stay-in-place forms, and submerged bulk zinc anodes. Selecting the best galvanic jacket for the application will help to address corrosion-induced deterioration and will preserve and extend the service life of concrete piles in the marine environment.]]></description>
      <pubDate>Tue, 11 Oct 2022 11:58:34 GMT</pubDate>
      <guid>https://trid.trb.org/View/2023461</guid>
    </item>
    <item>
      <title>Fatigue Characterization of Galvanized Welded Connections</title>
      <link>https://trid.trb.org/View/2015225</link>
      <description><![CDATA[Galvanizing is a common corrosion protection method used in highway structures, particularly for sign and lighting structures, and increasingly for bridge applications. There is some evidence of premature fatigue cracking occurring in in-service galvanized structures, and some limited studies have demonstrated lower fatigue resistance of galvanized specimens compared against non-galvanized specimens. These studies have been focused on a limited number of full-scale tests, and the issue of reduced fatigue strength of welded connections has not been studied in a systematic manner.
To investigate the fatigue performance of welded connections that have been galvanized, a series of 10 welded specimens will be tested under cyclic fatigue loading. The geometry of the fatigue specimens is shown in Figure 1. The specimens will be fabricated from two plates that have been joined with a submerged arc weld (SAW) and verified to be free of defects with radiographic tests.
Seven of the specimens will be galvanized before testing, and three of the specimens will be left as black steel (ungalvanized) and tested as control specimens. Galvanizing will be performed at the University of Kansas in the Learned Highbay; an active/charged galvanizing kettle is available for use in that facility for this project. All specimens to be galvanized will be dipped for a consistent amount of time (anticipated to be approximately 20 minutes) so that coatings are developed with similar thicknesses. Specimens will be prepared through degreasing and pickling or blasting before galvanizing.
It is anticipated that all fatigue tests will be performed at a stress range of 20 ksi, which is greater than the constant-amplitude fatigue limit for Category B fatigue details (16 ksi). Test results between galvanized and ungalvanized specimens will be compared to characterize the sensitivity of welded connections under fatigue loading to galvanizing. Fatigue testing will be performed using the closed-loop servo-controlled Instron universal testing machine in the Lutz Fatigue & Fracture Laboratory at KU. 
To supplement information gained through the fatigue tests, a series of Charpy V-Notch (CVN) specimens will also be tested, as a reasonable proxy for fracture resistance. The purpose of the CVN tests will be to study the toughness of galvanized steel vs. ungalvanized steel. Three groups of CVN specimens will be considered: ungalvanized CVNs, CVNs fabricated from the steel plate and then galvanized, and CVNs fabricated from the plate after it has been galvanized. Thirty CVN specimens from each group (90 total) will be tested using an impact hammer in the Lutz Fatigue & Fracture Laboratory at the University of Kansas.]]></description>
      <pubDate>Tue, 30 Aug 2022 17:27:47 GMT</pubDate>
      <guid>https://trid.trb.org/View/2015225</guid>
    </item>
    <item>
      <title>Hydrogen Solubility Effects in Galvanized Advanced High Strength Steels</title>
      <link>https://trid.trb.org/View/1779533</link>
      <description><![CDATA[Advanced high strength steels used in automotive body and structure applications are exposed to hydrogen during several steps of their processing. For galvanized sheet steel, one of these is the continuous galvanizing process, during which the sheet is prepared for coating in a H2-N2 furnace. This paper shows the relationship between hydrogen uptake in DP600 and DP980 grades, together with an IF steel control composition, and galvanizing process conditions. Hydrogen uptake is strongly dependent on the furnace atmosphere and the amount of martensite in the steel but has little dependence on the soaking time, the humidity of the furnace atmosphere, or the temperature within the usual intercritical annealing range. Rapid outgassing was observed during overageing prior to the zinc dipping. Slow strain rate tests showed that there was no loss of ductility in galvanized samples that had been treated in a 5% H2 atmosphere or that had been overaged before the galvanizing.]]></description>
      <pubDate>Thu, 30 Dec 2021 13:03:18 GMT</pubDate>
      <guid>https://trid.trb.org/View/1779533</guid>
    </item>
    <item>
      <title>Effect of Fuel-to-Air Ratio on Oxidation and Interfacial Structure in Galvanizing of a Dual-Phase Steel</title>
      <link>https://trid.trb.org/View/1874036</link>
      <description><![CDATA[

Automotive-grade high-strength steels are galvanized for improved corrosion resistance. However, selective oxidation of alloying elements during annealing heat-treatment may influence the subsequent zinc (Zn) coating quality. The formation of internal and external oxides depends on the alloy composition, especially the Si/Mn ratio, and the oxygen potential of the annealing atmosphere. In this work, a dual-phase (DP) steel was intercritically annealed with varied fuel-to-air ratios in a direct-fired furnace and then galvanized in a Zn bath with 0.2 wt% Al. The type of internal and external oxides and the interfacial structures between the steel substrate, the Al-Fe-Zn inhibition layer, and the Zn coating were examined by using site-specific focused ion beam (FIB) and transmission electron microscopy (TEM). It was found that for the high fuel-to-air ratio sample, the external oxide is a Mn-Si-O complex oxide and the internal oxide presents an inhomogeneous structure; for the medium fuel-to-air ratio sample, the external oxides are both MnO and Mn-Si-O oxides and the internal oxide presents a Si-O core surrounded by a Mn-Si-O shell; for the low fuel-to-air ratio sample, both the external and internal oxides are Mn-Si-O. The inhibition layer in all the samples appears to be continuous. Lift-off of surface oxides was observed in the high and medium fuel-to-air ratio samples. Possible mechanisms are discussed.
]]></description>
      <pubDate>Tue, 26 Oct 2021 14:25:42 GMT</pubDate>
      <guid>https://trid.trb.org/View/1874036</guid>
    </item>
    <item>
      <title>Optimizing the Geometric Configuration and Manufacturing Process of High Mast Illumination Poles [supporting dataset]</title>
      <link>https://trid.trb.org/View/1857959</link>
      <description><![CDATA[This work presents the development of a high-fidelity model that accounts for the cumulative effect of welding and hot- dip galvanizing on the determining the resulting residual stresses and deformations induced during the manufacturing process of high mast illumination poles (HMIPs). This model is meant to elucidate the root causes of weld toe cracks in HMIPs. A TxDOT pole-to-base plate connection detail was used as the reference model in the analysis. Welding was modeled using the plug-in Abaqus Welding Interface (AWI), which automatically implements a series of sequential thermal and mechanical analyses. Then, the welding stress results were used as initial input to the galvanizing analysis. The cumulative stress results were compared against simulations that only considered the galvanizing process. A parametric study was then conducted to quantify the variation in the residual stresses and equivalent plastic strain magnitudes induced during the welding and galvanizing of HMIPs due to changes in welding and galvanizing practices. The results revealed that the cumulative effects of the different processes involved in the manufacturing of HMIPs contribute to the formation of galvanizing cracks in HMIPs. Also, increasing the dipping submersion speed during galvanizing and lowering the torch temperature magnitude during welding results in fewer zones prone to cracking. Altering the angle of inclination effect did not have a significant impact on the results. Performing variations in the manufacturing practices used for the fabrication of HMIPs can contribute to reducing the extensive inspection procedures conducted post-galvanizing to identify cracks.]]></description>
      <pubDate>Wed, 07 Jul 2021 09:31:41 GMT</pubDate>
      <guid>https://trid.trb.org/View/1857959</guid>
    </item>
    <item>
      <title>Mitigation of Weldment Cracking in Steel Highway Structures Due to the Galvanizing Process</title>
      <link>https://trid.trb.org/View/1860921</link>
      <description><![CDATA[This report proposes modifications to the current AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals and the AASHTO LRFD Bridge Design Specifications that, if implemented, will help mitigate weldment cracking that occurs due to the galvanizing process. This should enable these assets to achieve their intended service life and eliminate related safety concerns. This report will be of immediate interest to state bridge and construction engineers and others involved in the different aspects of steel structures.]]></description>
      <pubDate>Mon, 28 Jun 2021 12:41:57 GMT</pubDate>
      <guid>https://trid.trb.org/View/1860921</guid>
    </item>
    <item>
      <title>Optimizing the Geometric Configuration and Manufacturing Process of High Mast Illumination Poles</title>
      <link>https://trid.trb.org/View/1769931</link>
      <description><![CDATA[This work presents the development of a high-fidelity model that accounts for the cumulative effect of welding and hot-dip galvanizing on the determining the resulting residual stresses and deformations induced during the manufacturing process of high mast illumination poles (HMIPs). This model is meant to elucidate the root causes of weld toe cracks in HMIPs. A Texas Department of Transportation (TxDOT)  pole-to-base plate connection detail was used as the reference model in the analysis. Welding was modeled using the plug-in Abaqus Welding Interface (AWI), which automatically implements a series of sequential thermal and mechanical analyses. Then, the welding stress results were used as initial input to the galvanizing analysis. The cumulative stress results were compared against simulations that only considered the galvanizing process.  A parametric study was then conducted to quantify the variation in the residual stresses and equivalent plastic strain magnitudes induced during the welding and galvanizing of HMIPs due to changes in welding and galvanizing practices. The results revealed that the cumulative effects of the different processes involved in the manufacturing of HMIPs contribute to the formation of galvanizing cracks in HMIPs.  Also, increasing the dipping submersion speed during galvanizing and lowering the torch temperature magnitude during welding results in fewer zones prone to cracking. Altering the angle of inclination effect did not have a significant impact on the results. Performing variations in the manufacturing practices used for the fabrication of HMIPs can contribute to reducing the extensive inspection procedures conducted post-galvanizing to identify cracks.]]></description>
      <pubDate>Thu, 25 Feb 2021 10:10:55 GMT</pubDate>
      <guid>https://trid.trb.org/View/1769931</guid>
    </item>
    <item>
      <title>Geometric Configuration Effects on the Formation of Weld Toe Cracks during the Galvanizing of High Mast Illumination Poles</title>
      <link>https://trid.trb.org/View/1763323</link>
      <description><![CDATA[Cracks at the pole-to-base plate connection of high mast illumination poles (HMIPs) are a major source of concern to highway transportation officials. Thermally induced deformations induced during the galvanizing process are known to introduce damages to the pole-to-base plate connection. In this study, finite element analyses were performed to evaluate the effects of geometric configuration variables on the response of the HMIPs during galvanizing, particularly in determining the stress demand magnitudes. The control variables of the study were base plate thickness, pole shaft wall thickness, and number of pole sides. The numerical results indicated that the stress demands were highest at locations near the pole-to-base plate connection. Reducing the base plate-to-pole thickness ratio and using poles with round shape were identified as effective approaches to reduce stress demands in HMIPs during galvanizing.]]></description>
      <pubDate>Wed, 27 Jan 2021 10:10:44 GMT</pubDate>
      <guid>https://trid.trb.org/View/1763323</guid>
    </item>
    <item>
      <title>Galvanizing-Induced Distortion in Steel Plate Girders. II: Effects of Welding and Galvanizing Practices</title>
      <link>https://trid.trb.org/View/1652469</link>
      <description><![CDATA[This paper, the second of a two-part series, presents a parametric study investigating the influence of welding and galvanizing practices on the susceptibility of welded plate girders to distortion during and after galvanizing. Three methods of welded fabrication were studied: welding in lay-down position, welding in the trough, and welding in the vertical position. In addition, galvanizing dipping and extraction speed, dwell time in the zinc bath, and dipping angle were examined as parameters. It was found that welding in the vertical position corresponded to the least distortion during galvanizing, especially for unstiffened plate girders. Dipping speed was also identified as an important parameter for reducing distortion, and faster dipping and extraction speeds resulted in less distortion during and after galvanizing. The results of this study provide guidance to engineers, galvanizers, and fabricators to minimize steel plate girder distortion so that they can more confidently use hot-dip galvanizing to protect their bridges, and the paper describes a modeling methodology that will enable future research in this field.]]></description>
      <pubDate>Tue, 22 Oct 2019 14:36:08 GMT</pubDate>
      <guid>https://trid.trb.org/View/1652469</guid>
    </item>
    <item>
      <title>Galvanizing-Induced Distortion in Steel Plate Girders. I: Effects of Girder Geometry</title>
      <link>https://trid.trb.org/View/1652468</link>
      <description><![CDATA[This study investigates the distortion behavior of steel plate girders under the cumulative influence of welding and hot-dip galvanizing processes and is presented in two papers. This paper presents the results of a parametric study on the effects of girder geometry (length, depth, flange and web thickness, and stiffener placement) on distortions during hot-dip galvanizing. Nonlinear simulations were carried out using the commercial software Abaqus. It was found that girder length did not strongly affect girder distortion trends, but changes in girder depth and flange-to-web-thickness ratio did. Including stiffeners was found to offer some benefit to controlling distortion during galvanizing; however, the results also indicated that more stiffeners were not necessarily better. The results supported industry recommendations. The results of this study provide guidance to engineers, galvanizers, and fabricators to minimize steel plate girder distortion so that they can more confidently use hot-dip galvanizing to protect their bridges, and it presents a novel modeling framework that will enable significant future work in this field of study.]]></description>
      <pubDate>Tue, 22 Oct 2019 14:36:08 GMT</pubDate>
      <guid>https://trid.trb.org/View/1652468</guid>
    </item>
  </channel>
</rss>