<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Transport Research International Documentation (TRID)</title>
    <link>https://trid.trb.org/</link>
    <atom:link href="https://trid.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMCIgLz48L3BhcmFtcz48ZmlsdGVycz48ZmlsdGVyIGZpZWxkPSJpbmRleHRlcm1zIiB2YWx1ZT0iJnF1b3Q7QnJpZGdlIGNhYmxlcyZxdW90OyIgb3JpZ2luYWxfdmFsdWU9IiZxdW90O0JyaWRnZSBjYWJsZXMmcXVvdDsiIC8%2BPC9maWx0ZXJzPjxyYW5nZXMgLz48c29ydHM%2BPHNvcnQgZmllbGQ9InB1Ymxpc2hlZCIgb3JkZXI9ImRlc2MiIC8%2BPC9zb3J0cz48cGVyc2lzdHM%2BPHBlcnNpc3QgbmFtZT0icmFuZ2V0eXBlIiB2YWx1ZT0icHVibGlzaGVkZGF0ZSIgLz48L3BlcnNpc3RzPjwvc2VhcmNoPg%3D%3D" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Transport Research International Documentation (TRID)</title>
      <url>https://trid.trb.org/Images/PageHeader-wTitle.jpg</url>
      <link>https://trid.trb.org/</link>
    </image>
    <item>
      <title>Fatigue Properties and Application Feasibility of CFRP Laminate as Cable in Long-Span Suspension Bridge with High-Speed Train Load</title>
      <link>https://trid.trb.org/View/2790092</link>
      <description><![CDATA[Carbon fiber reinforced polymer (CFRP) cable members have been tentatively applied in a few bridges and a spatial cantilever structure. This paper presents an evaluation method to discuss the feasibility of applying CFRP composite laminate as a cable in bridges, considering stiffness degradation induced by cumulative fatigue damage. The life prediction model is derived to simulate the propagation of fatigue damage in a CFRP laminate strap, and it shows good agreement with experimental data from cyclic tensile fatigue and residual ultimate strength tests. Furthermore, a train-track-bridge coupled vibration (TTBCV) model is developed to investigate the structural vibration behavior in a suspension bridge with hybrid CFRP cables. The practical fatigue damage indicates that CFRP laminates are effective as cable members in terms of fatigue performance under high-speed train loads.]]></description>
      <pubDate>Mon, 09 Nov 2026 11:32:48 GMT</pubDate>
      <guid>https://trid.trb.org/View/2790092</guid>
    </item>
    <item>
      <title>Study on mechanical performance of hot-cast anchorage for large-span spatial structure cable under high-temperature</title>
      <link>https://trid.trb.org/View/2719711</link>
      <description><![CDATA[This study aims to analyze the ultimate bearing capacity and failure modes of hot-cast anchorages, key specimens of cables in large-span spatial structures, under various high-temperature conditions. Steady-state high-temperature tests were conducted on hot-cast anchorages for two types of cables to investigate their mechanical behavior and failure modes. The tests revealed the high-temperature sliding behavior between the steel wires and the casting material. Furthermore, transient high-temperature tests were conducted to determine the ultimate failure time and failure modes of hot-cast anchorages for both types of cables. A comparison of the mechanical properties of the anchorages revealed variations in performance for cables of the same specifications under varying high-temperature conditions. Based on the test data, a bonding-slip constitutive model and a bearing capacity prediction model were developed for high-temperature. The results indicate that the ultimate bearing capacity of hot-cast anchorages exceeded the minimum required breaking force up to 300°C, with capacity decreasing as temperature increased. Moreover, the ultimate failure time decreased as the temperature increased during high-temperature transient tests.]]></description>
      <pubDate>Fri, 30 Oct 2026 14:26:57 GMT</pubDate>
      <guid>https://trid.trb.org/View/2719711</guid>
    </item>
    <item>
      <title>Influence and compensation method of wire resistance on measurement accuracy of elasto-magnetic sensors for tension monitoring of prestressed strand</title>
      <link>https://trid.trb.org/View/2719419</link>
      <description><![CDATA[Elasto-magnetic (EM) methods have been widely adopted in civil engineering for the tension monitoring of cables, hangers, and prestressed strands due to their noncontact and nondestructive properties. However, in practical applications, variations in the installation positions of EM sensor often lead to significant differences in wire length. This results in changes in wire resistance, which can affect the measurement results. Therefore, in this study, we developed a multiphysics coupling finite element model to systematically analyze the influence of wire resistance on the output signals and measurement results of EM sensors. A tension calibration experiment was conducted to verify the effectiveness of the simulation results and assess the influence of wire resistance on the measurement results. To mitigate the resistance effects, constantan wire resistors were used to compensate for wire resistance. The experimental findings indicate that compensation reduced the full-scale relative error of the EM sensor from (−9.1% to 7.2%) before compensation to (−4.9% to 4.5%) afterward, thereby enhancing the measurement stability and accuracy. Finally, EM sensors with resistance compensation were applied to an external prestressing reinforcement project for a prestressed concrete bridge. Measurement results with a relative error of less than 4% were obtained during the tensioning process. Long-term tension monitoring was performed. The results demonstrate that EM sensors with resistance compensation can provide accurate and stable tension measurements, thereby supporting the reliability of this approach for real-world applications.]]></description>
      <pubDate>Thu, 29 Oct 2026 11:47:59 GMT</pubDate>
      <guid>https://trid.trb.org/View/2719419</guid>
    </item>
    <item>
      <title>Experimental and Numerical Study on the Response of Stay Cables under Vehicle Collision on Cable-Stayed Bridges</title>
      <link>https://trid.trb.org/View/2772950</link>
      <description><![CDATA[Although numerous studies have focused on vehicle impacts on bridge piers, the effects of direct collisions on stay cables in cable-stayed bridges remain relatively underexplored. To address this gap, this study investigated the dynamic responses of stay cables under vehicular impact through a combination of scaled physical tests and numerical simulations. Inclined scaled cable specimens were tested to replicate realistic collision conditions, capturing dynamic responses such as impact force evolution, cable deformation, and localized damage. The test results indicated pronounced plastic deformation and slippage near the anchorage zones, but no complete cable failure was observed. A finite-element model was developed and calibrated based on the experimental data, and then extended to simulate vehicle-to-cable impacts on a representative bridge at various collision angles. The numerical results showed that guardrails could reduce peak impact forces by up to 84.7% under small-angle impacts. However, as the collision angle increased, the redirection effectiveness of the guardrail was diminished, resulting in a higher probability of direct vehicle–cable contact and increased impact severity. The magnitude of the impact force also increased notably with larger collision angles.]]></description>
      <pubDate>Fri, 25 Sep 2026 10:51:25 GMT</pubDate>
      <guid>https://trid.trb.org/View/2772950</guid>
    </item>
    <item>
      <title>Development Length of a High-Strength Steel Wire in a Bridge Cable Changing with Wrapping Force and Axial Load</title>
      <link>https://trid.trb.org/View/2708353</link>
      <description><![CDATA[This paper studies the force transfer of a large bridge cable containing a broken wire under wrapping force and axial load. Following our recent work, the wrapping force transferred through the contacts between the wires can be represented by a center-center force network with the Hertz contact, and the axial load is transferred to the broken wire by frictional shear along the contact in the axial direction. When a wire is broken, the stress is released at the free surfaces along the crack. However, the shear stress transfer from the neighboring wires to the broken wire concentrates through shear lag; therefore, the broken wire can regain load resistance over a certain development length, which can be estimated by stress analysis of the homogenized cylinder using the finite element method (FEM). The development length decreases when the wrapping force increases because the higher effective stiffness and interfacial shear resistance lead to a higher shear load transfer capacity. Consequently, given a specific wrapping force, the development length can be computed, allowing the prediction of the critical axial load of a cable with multiple broken wires with a certain spacing.]]></description>
      <pubDate>Thu, 17 Sep 2026 10:09:39 GMT</pubDate>
      <guid>https://trid.trb.org/View/2708353</guid>
    </item>
    <item>
      <title>An Improved Tension Evaluation Approach for Smart Strands</title>
      <link>https://trid.trb.org/View/2778111</link>
      <description><![CDATA[Monitoring strand tension is crucial for bridge safety assessment and reinforcement design. Smart strands, composed of a straight core wire embedded with a fiber grating and six helical wires, have been developed for tension monitoring. In this study, an improved tension evaluation method based on smart strands was developed. First, the external load-induced strain of the core wire was obtained by applying a developed complete temperature model to temperature and wavelength measurements of the grating, which can fully deduce the temperature-induced strain. Subsequently, an analytical iterative model, accounting for the off-axis effect of the helical wires, was derived to convert the core wire strain into the corresponding strain in the helical wires. Finally, the total tension of the smart strand was calculated by summing the contributions from the core and helical wires based on their respective strains. The proposed method was validated using laboratory experiments, demonstrating that the complete temperature compensation model exhibits universality across statically determinate and indeterminate structures, achieving an error reduction exceeding 55.6% in statically indeterminate systems. Furthermore, the proposed tension evaluation method achieves estimation errors below 2.5% and reduces maximum tension errors by 56.6% compared with conventional methods that directly use the core wire strain as the average strain. The results indicate that traditional temperature compensation models for optical fiber sensors cannot fully eliminate temperature effects, mainly because of the neglect of temperature field effects rather than sensor limitations.]]></description>
      <pubDate>Wed, 16 Sep 2026 16:15:41 GMT</pubDate>
      <guid>https://trid.trb.org/View/2778111</guid>
    </item>
    <item>
      <title>Equivalent boundary stiffness identification based on CMA-ES for refined cable tension inversion</title>
      <link>https://trid.trb.org/View/2775439</link>
      <description><![CDATA[Construction control of cable-supported bridges requires reliable vibration-based refined cable-tension identification, yet its accuracy is often limited by uncertain elastic end restraints that are difficult to quantify in practice. This study presents a modal-data-driven framework for refined cable-tension evaluation under uncertain boundary conditions. The framework combines a finite-element forward model with two coupled inverse modules: equivalent boundary-stiffness identification and cable-tension inversion. A Monotone–Bracketing Newton scheme is developed for tension inversion, integrating bracketing, MAC-based modal-branch locking, and sensitivity-driven Newton updates. Boundary stiffness is identified by optimizing non-dimensionalized variables through a tailored covariance matrix adaptation evolution strategy using a joint objective based on frequency residuals. Numerical studies on 50 cables show that, when cable tension is estimated using the 100 identified sets of equivalent boundary stiffnesses, the 95th-percentile error is 5.59 × 10⁻⁴. Laboratory strand tests under three unknown boundary conditions yield tension errors mostly within 0.5%, with a maximum of 0.92%. An in-construction cable-stayed bridge case further demonstrates practical applicability, with tension errors within 1% for instrumented cables, stage-wise tension differences mostly within 2%, and a maximum main-girder vertical alignment deviation of about 5 cm. The results demonstrate that the proposed framework provides an effective and practical approach for vibration-based refined evaluation of cable tension in the presence of boundary uncertainty.]]></description>
      <pubDate>Wed, 16 Sep 2026 14:40:15 GMT</pubDate>
      <guid>https://trid.trb.org/View/2775439</guid>
    </item>
    <item>
      <title>Analytical evaluation of cable corrosion effects on the residual prestressing coactive state in post-tensioned concrete elements</title>
      <link>https://trid.trb.org/View/2705583</link>
      <description><![CDATA[The paper provides an original analytical evaluation of the effects of cable corrosion on the prestressing coactive state in post-tensioned concrete elements (namely, beams and stays in prestressed bridges), in which steel cables are made adherent through subsequent cast-in-situ grouting. The corrosion is assumed to be homogeneously distributed over a finite portion of the sheathing duct characterized by lack of mortar injection, and modeled as a uniform cross-section loss. The study analytically demonstrates that the reduction of the cross-sectional area of the prestressing steel cables due to corrosion generates both (I) a loss of the prestressing force and (II) a stress redistribution within the residual cross-sectional area of the cables, which are limited to the zone lacking grouting. Ready-to-use closed-form mathematical expressions for these two effects are derived allowing direct quantification of the corrosion-induced variation of the prestressing state, for the two cases of concentric and eccentric tendons, and validated against experimental results available in the scientific literature. A numerical application to three typical existing bridge elements is also provided. The fundamental result is that the loss of the prestressing force is approximately equal to the cross-section loss, while the stress redistribution is comparatively small, providing a cable stress increase below 5% for bridge decks and below 25% for stays, even for highly corroded cables.]]></description>
      <pubDate>Thu, 03 Sep 2026 09:37:47 GMT</pubDate>
      <guid>https://trid.trb.org/View/2705583</guid>
    </item>
    <item>
      <title>Unstrained cable length assessment for suspension bridge's individual strands: An analytical method</title>
      <link>https://trid.trb.org/View/2703123</link>
      <description><![CDATA[Accurately determining each strand's unstrained cable length (UCL) for a suspension bridge is critical for ensuring structural safety and minimizing construction errors. The traditional methods often overlook the distribution of strands, particularly the spatial curves within splay saddles and anchor spans, which may lead to significant deviations in strand length. Hence, a novel calculation method for determining the individual strands' UCLs was established, specifically focusing on the spatial configurations within the splay saddle and the anchor span. A simplified formula was developed to estimate the elevation sensitivity coefficient at mid-span, facilitating rapid adjustment to strand configurations during construction. The results demonstrate that the proposed approach achieves a maximum error of only 0.03‰ of the total strand length when compared to measured data, with most discrepancies occurring in the anchor span due to variations in anchoring positions. Additionally, it is observed that the longest strand exceeded the shortest by 0.812 m, with upper strands in the section being longer than the central strand, leading to a symmetrical UCL distribution in the main and side spans. Still, the distributed anchoring positions impact UCL distribution symmetry significantly in anchor spans. Moreover, the sensitivity of mid-span elevation to UCL increases with the span length. This study offers a valuable approach to improving the precision of the cable strand configuration, contributing to better construction control.]]></description>
      <pubDate>Tue, 01 Sep 2026 09:09:46 GMT</pubDate>
      <guid>https://trid.trb.org/View/2703123</guid>
    </item>
    <item>
      <title>Lightweight YOLO-LYE enables edge intelligence for climbing robotic inspection of the bridge cable sheath defects</title>
      <link>https://trid.trb.org/View/2732014</link>
      <description><![CDATA[The inspection of polyethylene (PE) sheaths on cable-stayed bridge cables is critical for maintaining structural integrity. However, significant challenges in efficiency, safety, and precision arise when traditional methods are employed. To address the limitations, a lightweight deep learning model named You Only Look Once-Lightweight, Yield and Edge-optimized (YOLO-LYE) is proposed. The model has been optimized for deployment on edge-based climbing robots to enable real-time, high-accuracy defect detection. Three core innovations are integrated: (1) A novel hybrid backbone is proposed, introducing the newly designed Cross-Scale Feature Fusion Module (CCFM) into a streamlined ShuffleNetV2 framework to achieve an optimal balance between computational efficiency and feature representation capability. (2) The feature alignment pathway is re-engineered through the strategic replacement of standard up/down-sampling operations with the dynamic upsampler (DySample) and a deformable convolution-based downsampling module (C3k-LD), forming a novel combination that is specifically designed to enhance sensitivity to small-scale defects. (3) The complete model is optimized for deployment on edge devices via the high-performance ncnn framework, facilitating real-time robotic inspection. Computational complexity is reduced by 52.4%, and the number of parameters is decreased by 64.1% compared to YOLOv11, while robust feature representation is maintained. Field validation was conducted on 236 stay cables. Detection accuracy exceeding 90% was achieved across defect categories under operational conditions. The work establishes a scalable framework for automated, high-precision infrastructure inspection in edge computing environments.]]></description>
      <pubDate>Tue, 28 Jul 2026 16:13:14 GMT</pubDate>
      <guid>https://trid.trb.org/View/2732014</guid>
    </item>
    <item>
      <title>Calculation Method for Deformation of Three-Tower Cable-Stayed Bridges</title>
      <link>https://trid.trb.org/View/2731942</link>
      <description><![CDATA[The structural deformation induced by live loads represents a significant consideration in the design of three-tower cable-stayed bridges. The study proposes a deformation calculation method for three-tower cable-stayed bridges, which can be used to assess whether the structural stiffness meets requirements during the preliminary design stage. Based on the elastic foundation beam theory, analytical expressions for the longitudinal constraint stiffness of the cables and the main girder on the middle tower are derived. Furthermore, analytical formulas for the longitudinal displacement at the top of the middle tower and the midspan deflection of the loaded span under live load are established. Finite element analysis demonstrates strong concordance between the theoretical values and the results obtained from the model. In addition, the influence of cable and girder design parameters on their longitudinal constraint effects is analyzed based on the proposed analytical expressions. The study indicates that once the cable stress level reaches 600 MPa, further increases in stress yield diminishing returns in enhancing constraint stiffness; increasing the cable cross-sectional area is more effective in improving longitudinal constraint stiffness than enlarging the main girder’s moment of inertia.]]></description>
      <pubDate>Tue, 21 Jul 2026 15:15:18 GMT</pubDate>
      <guid>https://trid.trb.org/View/2731942</guid>
    </item>
    <item>
      <title>Evaluation of multi-modal vortex-induced vibrations of damped cables using an experimentally tailored wake oscillator model</title>
      <link>https://trid.trb.org/View/2684607</link>
      <description><![CDATA[Vortex-induced vibrations (VIVs) in bridge cables are usually mitigated using dampers. Modeling the vibrations versus mass-damping ratio (Scruton number, Sc) is critical for evaluating the control efficiency. In this study, the wake oscillator model of Facchinetti et al. (2004a) is tailored to enhance the accuracy of VIV simulations by: (i) modifying the fluid-added damping term and treating it as a polynomial of Sc number for better capturing the Sc-amplitude curve (i.e., Griffin plot); (ii) calibrating the aeroelastic parameters using experimental data for a prototype cable model with dimpled surfaces. On this basis, by formulating the cable-wake equations via the Galerkin method, an analysis framework is developed to predict the multi-modal VIVs of flexible cables with attached dampers. This framework is further applied to a case study on an ultra-long stay cable. First, the oscillation predictions are validated against field measurements. Subsequently, the oscillations with and without control are considered to reveal the limitations of existing dampers and prove the efficiency of a supplementary damper. The results show that the model can reliably simulate the multi-modal VIVs and evaluate damper performance. Finally, two interesting phenomena, i.e., mode competition at lock-in overlapping and oscillation reduction due to non-uniform flows, are discussed.]]></description>
      <pubDate>Mon, 13 Jul 2026 13:58:16 GMT</pubDate>
      <guid>https://trid.trb.org/View/2684607</guid>
    </item>
    <item>
      <title>Corrosion fatigue degradation mechanisms and damage assessment methods of bridge cables: A state-of-the-art review</title>
      <link>https://trid.trb.org/View/2687295</link>
      <description><![CDATA[To advance research on the degradation mechanisms and prediction methods for the load-bearing capacity of cable-supported bridges, the performance degradation mechanism and evaluation method of steel wire within cables and its cable bodies in long-span cable bridges under multi-field coupling of environmental corrosion and fatigue load are systematically combed. Firstly, the study elucidates the influencing factors of corrosion fatigue degradation in cables, clarifying the micro-development mechanisms of corrosion fatigue under environmental corrosion, mechanical loading, and material interface conditions. Secondly, the process of mechanical property degradation in high-strength steel wires within cables due to corrosion fatigue coupling is analyzed, and characterization methods based on damage mechanics and fracture mechanics are summarized. Furthermore, the overall degradation process, mechanical properties, and fatigue life of the cables are evaluated. Finally, subsequent research priorities regarding the corrosion damage mechanism and performance assessment of the cables under multi-factor coupling are discussed and projected. The results indicate that corrosion is the fundamental cause of the degradation in the mechanical properties of steel wires. Corrosion pits, serving as fatigue crack initiation sites, significantly deteriorate wire performance through stress concentration. Macroscopically, the spatial configuration of pitting dominates crack initiation and propagation pathways; microscopically, crack initiation correlates with iron and manganese compounds, and stress corrosion accelerates their expansion. The overall performance and fatigue life of cables are significantly affected by the spatial characteristics of steel wires, and steel wires at different positions exhibit an uneven degradation process due to differences in the propagation paths of corrosive media or stress distribution. As long-span cable-supported bridges enter a period of concentrated emergence of diseases in the next decade, further developing and expanding research on the bearing capacity degradation mechanism and prediction methods under multi-factor coupling of cables has become a key task to ensure their long-term service safety and performance.]]></description>
      <pubDate>Fri, 10 Jul 2026 09:42:19 GMT</pubDate>
      <guid>https://trid.trb.org/View/2687295</guid>
    </item>
    <item>
      <title>Torsional behavior of semi-parallel wire cables under axial tension: An analytical algorithm</title>
      <link>https://trid.trb.org/View/2685133</link>
      <description><![CDATA[The coupled tension-torsion behavior of semi-parallel wire cables (SPWCs) is critical to the construction safety and in-service performance of cables and hangers in long-span bridges. Based on Costello’s elastic theory for wire ropes and Love’s theory for spatial curved rods, this study proposed an analytical model to characterize the coupled tension-torsion behavior of SPWCs and developed a corresponding solution algorithm. The model established the mechanical equilibrium equations for the wires by considering the bending moments, torques, shear forces, and axial forces. Moreover, the model accounted for the dynamic evolution of the helical wires’ lay angle and helix radius throughout the loading process. The reliability of the model was validated against experimental data and finite element (FE) simulation results. The effects of boundary conditions, initial lay angle, and the number of wire layers on the axial mechanical behavior of SPWCs were systematically investigated. The results indicated that the proposed model can accurately predict the elastic response of SPWCs under axial tension, with a mean absolute percentage error below 5% relative to FE and experimental results. Boundary conditions were identified as a dominant factor for the axial mechanical behavior of SPWCs. When torsionally restrained (AUTR), the SPWC’s mechanical behavior was equivalent to that of a solid steel rod, remaining insensitive to the initial lay angle and the number of wire layers. Conversely, under torsionally unrestrained conditions (AUTU), the significant tension-torsion coupling effect led to a nonlinear degradation in the axial stiffness of SPWCs. Compared with the AUTR condition, the SPWC exhibited a 29.2% reduction in its initial effective modulus under the AUTU condition. This degradation was further exacerbated by increased initial lay angle and the number of wire layers. As the initial lay angle was increased from 2° to 4°, the effective modulus of the SPWC was reduced by more than 16%. Expanding the total wire layers from 1 to 15 resulted in a 26.1% reduction in the initial effective modulus of the outermost layer.]]></description>
      <pubDate>Thu, 09 Jul 2026 13:29:25 GMT</pubDate>
      <guid>https://trid.trb.org/View/2685133</guid>
    </item>
    <item>
      <title>Aerodynamic control of galloping in lamp-attached stay cables using perforated fairing plates</title>
      <link>https://trid.trb.org/View/2685113</link>
      <description><![CDATA[Stay cables with rectangular lamp fixtures in urban bridges are susceptible to galloping instability. In this study, an alternative aerodynamic countermeasure, i.e., perforated fairing plates, is proposed to address the galloping issue. Wind tunnel experiments involving force and vibration measurements on sectional cable models are conducted to evaluate the galloping control from both quasi-steady and unsteady perspectives. The force measurements, together with quasi-steady analysis, show that the countermeasure eliminates the pronounced negative slope of the lift coefficient observed in the uncontrolled cable at attack angles of 14°–18°, and maintains the aerodynamic stability of the cable across all attack angles. The unsteady vibration measurements demonstrate that the countermeasure increases the critical galloping velocity of the cable at an unfavorable attack angle of 16° from 4.87 m/s to above 16.7 m/s. Moreover, simplified computational fluid dynamics (CFD) simulations are performed to visualize the flow characteristics, including streamlines, pressure fields, and vorticity. The results indicate that the flow pattern around the cable at larger attack angles appears to shift from an asymmetric one-sided to a pseudo-symmetric two-sided flow separation due to the countermeasure. Finally, parametric studies suggest a possible minimum size and an effective porosity range for the fairing plates.]]></description>
      <pubDate>Thu, 09 Jul 2026 13:29:25 GMT</pubDate>
      <guid>https://trid.trb.org/View/2685113</guid>
    </item>
  </channel>
</rss>