<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Transport Research International Documentation (TRID)</title>
    <link>https://trid.trb.org/</link>
    <atom:link href="https://trid.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMCIgLz48L3BhcmFtcz48ZmlsdGVycz48ZmlsdGVyIGZpZWxkPSJpbmRleHRlcm1zIiB2YWx1ZT0iJnF1b3Q7Q29vbGFudHMmcXVvdDsiIG9yaWdpbmFsX3ZhbHVlPSImcXVvdDtDb29sYW50cyZxdW90OyIgLz48L2ZpbHRlcnM%2BPHJhbmdlcyAvPjxzb3J0cz48c29ydCBmaWVsZD0icHVibGlzaGVkIiBvcmRlcj0iZGVzYyIgLz48L3NvcnRzPjxwZXJzaXN0cz48cGVyc2lzdCBuYW1lPSJyYW5nZXR5cGUiIHZhbHVlPSJwdWJsaXNoZWRkYXRlIiAvPjwvcGVyc2lzdHM%2BPC9zZWFyY2g%2B" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Transport Research International Documentation (TRID)</title>
      <url>https://trid.trb.org/Images/PageHeader-wTitle.jpg</url>
      <link>https://trid.trb.org/</link>
    </image>
    <item>
      <title>Study on Temperature Rise and Heat Dissipation of Micro Electric Vehicle Drive Motor Based on Multi-Physics Coupling</title>
      <link>https://trid.trb.org/View/2777838</link>
      <description><![CDATA[This paper is mainly about heat dissipation and improvement technology, aiming at solving the problem that the driving motor of 4 low-speed electric vehicles has too high a rising speed when running under complicated working conditions. Core losses and conductor losses are calculated by using the finite element method as well as known empirical formulas, and magnetic eddy loss at three operating conditions (normal condition, maximum speed, and peak torque. The computed heat loads are then used to establish the complete 3- dimensional model of thermal analysis.As shown in Figure 3, without active cooling, the hottest conductors would be at about 141°C (Class-B Insulation limit). Therefore, three different liquid cooling designs (helical channel, serpent channel, and annular flow) have been designed and analyzed. A coupled thermal- fluid simulation has been performed on the helix structure, which showed better results, so we selected it to be optimized.The optimization is performed using central composite design, genetic algorithms for response surfaces, and multi-objective evolutionary optimization (NSGA-II). The objective function is to simultaneously achieve a low maximum working temperature as well as good heat transfer properties by changing the geometry of cooling channels.The cooling of the motor as well as the suction pressure was optimized, after which a decrease by up to 31.1°C (up 8.6% on the maximum temperature) was observed. Also, pressure drop reduction as much as 23% along with substantial increases in both the heat transfer performance and reliability.]]></description>
      <pubDate>Wed, 16 Sep 2026 09:15:35 GMT</pubDate>
      <guid>https://trid.trb.org/View/2777838</guid>
    </item>
    <item>
      <title>Advanced Thermal Management for High-Tonnage EVs: Increasing Coolant Flow and Reducing Energy Losses</title>
      <link>https://trid.trb.org/View/2761933</link>
      <description><![CDATA[With the increasing tonnage of electric heavy commercial vehicles, there is a growing demand for higher power and torque-rated traction motors. As motor ratings increase, efficient cooling of the EV powertrain system becomes critical to maintaining optimal performance. Higher heat loads from traction motors and inverters pose significant challenges, necessitating an innovative cooling strategy to enhance system efficiency, sustainability, and reliability.Battery-electric heavy commercial vehicles face substantial cooling challenges due to the high-pressure drop characteristics of conventional traction system cooling architectures. These limitations restrict coolant flow through key powertrain components and the radiator, reducing heat dissipation efficiency and constraining the operating ambient temperature range. Inefficient cooling also leads to increased energy consumption, impacting the overall sustainability of electric mobility solutions.This paper presents a novel approach of optimizing coolant flow by reconfiguring the traction system layout and redesigning the coolant flow paths. These enhancements increase coolant flow by 100–200% compared to conventional systems, allowing the coolant pump to operate within its peak efficiency range. As a result, pumping power consumption is reduced by at least 33%, minimizing parasitic losses, improving vehicle range, and supporting green mobility initiatives by reducing energy waste.The increased coolant flow through the radiator enhances the tube-side heat transfer coefficient, significantly improving radiator heat dissipation and allowing for higher ambient temperature operation. Additionally, the optimized cooling system enables lower fan speeds, reducing both power consumption and cooling fan noise. This verified thermal management strategy, successfully implemented in production-ready heavy-duty electric vehicles, has effectively prevented traction propulsion motor power de-rating, leading to improved vehicle performance, energy efficiency, and long-term sustainability.Furthermore, a unique control strategy has been developed to dynamically regulate coolant pump and radiator fan operation by continues monitoring of each aggregate device temperatures. This optimized thermal management system ensures robust and efficient cooling.]]></description>
      <pubDate>Wed, 19 Aug 2026 13:48:43 GMT</pubDate>
      <guid>https://trid.trb.org/View/2761933</guid>
    </item>
    <item>
      <title>Thermal System Design of Inter-City Fuel Cell Electric Bus</title>
      <link>https://trid.trb.org/View/2761811</link>
      <description><![CDATA[In current scenario, demand for alternate energy is increasing due to depletion of fossil fuels and countries working to achieve carbon neutrality by 2050. Hydrogen being a cleaner fuel, many OEMs across the world started to work on various strategies like hydrogen combustion engine and fuel cell. Passenger vehicles like buses are at the lookout for fuel cell technology at faster rate than other commercial vehicles. In fuel cell vehicles, cooling system design is critical & complex since it includes fuel cell cooling, Power electronics cooling & battery cooling. In this paper, cooling system design of a Fuel cell electric bus for inter-city application is demonstrated. Radiators and Fans are designed considering overall heat rejection and Coolant inlet temperature requirements of components. Cooling system circuit and pump is decided to meet the coolant flow rate targets. Flow simulation and thermal simulation done with the help of simulation models built using software KULI to predict coolant flow rate and temperature across each component. Fuel cell circuits, Power electronic circuits, Battery circuits modelled in KULI with all components in the circuit. KULI predicted results signifies good co-relation with actual results.]]></description>
      <pubDate>Wed, 19 Aug 2026 13:48:42 GMT</pubDate>
      <guid>https://trid.trb.org/View/2761811</guid>
    </item>
    <item>
      <title>Experimental Evaluation of HCV Cooling Module Assembly Using 7-Actuator Multiaxial Vibration Testing</title>
      <link>https://trid.trb.org/View/2761803</link>
      <description><![CDATA[This paper presents an innovative in-lab accelerated testing approach for chassis-mounted components, with a particular focus on the cooling module of commercial vehicles. The proposed method simulates real-time data acquired from field operations and replicates all critical chassis modes, including torsion. Additionally, real-time coolant circulation at specified pressure and temperature maintenance are feasible during durability testing, enhancing the realism of the test environment. The cooling modules, comprising the radiator, intercooler, and charge air cooler (CAC), often experience failures due to various multi-axial inputs and chassis modes.This paper introduces an innovative methodology for replicating field conditions in the lab, utilizing seven servo-hydraulic actuators to simulate multi-axial inputs. The accuracy of in-lab simulation for the acceleration levels at input and response locations of the cooling module exceeds 90%. This makes it a preferred choice for test engineers to simulate field failures or validate designs well in advance of final production, thereby avoiding issues at later stages of vehicle launch.This innovative approach offers flexibility to accelerate the test duration while ensuring the retention of over 90% of the damage observed in real-world conditions. By utilizing the same chassis frame and mounting locations, the test maintains consistent boundary conditions, providing reliable and accurate results. This method significantly enhances the efficiency and effectiveness of testing processes for commercial vehicle components, ensuring robust and reliable performance. [4]]]></description>
      <pubDate>Wed, 19 Aug 2026 13:48:42 GMT</pubDate>
      <guid>https://trid.trb.org/View/2761803</guid>
    </item>
    <item>
      <title>Design and Optimization of Diesel Engine Cold Start Heating System under Extreme Cold Conditions</title>
      <link>https://trid.trb.org/View/2742610</link>
      <description><![CDATA[With the goal of enhancing diesel engine adaptability to low-temperature environments and exploring cold-start potential at - 50 °C, this paper develops a one-dimensional simulation model for the cold-start system. The model is based on a method that utilizes a diesel heater to warm the coolant, which in turn heats the engine block and oil. The heating condition of coolant and oil of a 10-cylinder V-type engine within a specified time under a -50 °C environment is studied through simulation. We further optimized the cold-start process by enhancing the coolant flow distribution within each circulation circuit to improve overall thermal management and start-up efficiency. The results show that: at an ambient temperature of -50 °C, with a heating power of 80 kW, a total flow rate of 110 L/min, and an engine block flow rate of not less than 54 L/min, the diesel engine can raise the coolant temperature at the engine outlet to 40 °C and the oil temperature to -35 °C within 20 minutes. Through flow optimization, by maximizing the flow rate of the engine block heating circuit and reducing the flow diversion of the intercooler, the coolant temperature at the engine outlet can reach 40 °C in 18.9 minutes, while the oil is heated to -34.9 °C, and the final heating coolant temperature reaches 44.4 °C at 20 minutes. Compared to the situation without flow optimization, the time for the engine outlet coolant temperature to reach 40 °C was shortened by 0.55 minutes, and the final heating coolant temperature increased by 2.2 °C. Based on relevant experiments and the dynamic viscosity curve of 5 W engine oil, this paper holds that the starting conditions of a diesel engine can be met when the engine outlet coolant temperature reaches 40 °C, and the engine oil temperature reaches -35 °C.]]></description>
      <pubDate>Mon, 03 Aug 2026 15:42:11 GMT</pubDate>
      <guid>https://trid.trb.org/View/2742610</guid>
    </item>
    <item>
      <title>A Comprehensive CFD-Driven Approach to Battery Thermal Modeling and Cooling System Optimization</title>
      <link>https://trid.trb.org/View/2724728</link>
      <description><![CDATA[With the continued expansion of electric mobility, liquid-cooled thermal management systems have become indispensable for ensuring the performance, durability, and safety of automotive battery packs. This work presents a novel cooling-plate design that integrates offset strip-fin turbulators to enhance convective heat transfer between lithium-ion cells and the circulating coolant. A comprehensive multi-region CFD model of the full battery pack is developed, incorporating an implicit lumped-parameter representation of cell heat generation. The numerical predictions are validated against dedicated experimental measurements available in the literature. Subsequently, a parametric study is conducted in which the number of hydraulic sub-modules and the inlet/outlet configurations are systematically varied to generate all feasible design permutations. The resulting configurations are compared to assess thermal performance and to quantify the benefits—as well as the potential penalties—introduced by the turbulators relative to the experimentally validated baseline.]]></description>
      <pubDate>Tue, 21 Jul 2026 11:41:24 GMT</pubDate>
      <guid>https://trid.trb.org/View/2724728</guid>
    </item>
    <item>
      <title>Multiphysical Modeling of a Direct-Cooled Litz Wire Winding for a PMSM Using Surrogate Models</title>
      <link>https://trid.trb.org/View/2724700</link>
      <description><![CDATA[In permanent magnet synchronous machines (PMSMs) ohmic losses occur in the stator windings. Reducing these losses contributes to a higher efficiency and increases the vehicles range. An effective approach to reduce frequency-dependent AC conduction loss is the use of litz wires. In addition, direct cooling helps to reduce DC conduction loss and winding temperatures. Therefore, this work presents a multiphysical modeling approach of a direct-cooled litz wire winding in a PMSM. It combines loss modeling of the winding with novel thermal and hydraulic calculation methods. AC conduction loss due to skin and proximity effect and DC conduction loss are modeled temperature dependent. Scaled-down conjugate heat transfer simulations are used to determine the heat transfer coefficient (HTC) between wires and coolant. Additionally, the pressure drop is derived and converted into parameters for use in a porous media model. The derived parameters are used to generate surrogate models to enable computationally efficient predictions. Using the developed methods a case study is carried out. The influence of the number of turns per slot, litz wire diameter and number of parallel litz wires is investigated. In order to isolate the influence of the winding configuration, the geometry of the PMSM and the coolant volume flow remain constant. Performance indicators are energy consumption during a duty cycle, winding mass and pressure drop. Based on this study it is shown that the stator winding design is a multiphysical compromise. The method enables a targeted design of the winding configuration with respect to various objectives and facilitates the assessment of their influencing factors on the overall machine characteristics under conflicting performance requirements.]]></description>
      <pubDate>Tue, 21 Jul 2026 11:41:23 GMT</pubDate>
      <guid>https://trid.trb.org/View/2724700</guid>
    </item>
    <item>
      <title>Optimization of Preheating Energy Distribution for Low-Temperature Cold Starts in Diesel-Electric Hybrid Vehicles</title>
      <link>https://trid.trb.org/View/2732226</link>
      <description><![CDATA[To minimize energy input and preheating time, this study first analyzed the energy consumption of intake air, lubricating oil, and coolant preheating through simulations. Temperature rise data were collected under various heating parameters. Next, simulations evaluated the hybrid power system’s resistance characteristics immediately after startup and the combustion parameters during the first cycle post-ignition under different temperatures. The temperature thresholds for successful start-up were identified, defining the feasible domain for optimization. Optimization calculations aimed to minimize preheating time and energy input, constrained by maximum preheating power. Results show that intake air heating has the greatest impact on start-up success, followed by lubricating oil heating. It is recommended to increase energy allocation to intake air and lubricating oil heating. This optimized strategy reduces preheating time and energy input by approximately 26% without changing the preheating equipment.]]></description>
      <pubDate>Tue, 21 Jul 2026 11:36:51 GMT</pubDate>
      <guid>https://trid.trb.org/View/2732226</guid>
    </item>
    <item>
      <title>Evaluating Volume and Hardness change in Fluorocarbon and Ethylene Propylene
                    Rubber Elastomers: Effects of Fluid Aging
                </title>
      <link>https://trid.trb.org/View/2712142</link>
      <description><![CDATA[Abstract:  This research paper investigates the performance of FKM (Fluorocarbon) seal material when exposed to a 50:50 ethylene glycol-water mixture. The study aims to determine the volume change percentage and Hardness change of FKM elastomers under standardized testing conditions. The experimental approach follows ASTM D471 and ASTM 2240 guidelines, focusing on weight and hardness measurements of the test samples to establish a success criterion. The results provide critical insights into the chemical compatibility and durability of FKM elastomers in Aerospace and industrial applications where ethylene glycol-water mixtures are commonly used. The findings contribute to enhanced material selection and design considerations for sealing applications subjected to glycol-based fluids. Samples of FKM material were immersed in the fluid at controlled temperatures and durations, simulating real-world operational conditions. The primary metric of interest, volume change percentage and Hardness change, were assessed through precision measurement techniques. Weight changes before and after immersion were also recorded to correlate material absorption characteristics with the success criteria. Success thresholds were established based on industry requirements for seal integrity and operational reliability. Preliminary results indicate that FKM exhibits minimal volume expansion and hardness change under specified conditions, aligning with the acceptance criteria. These findings support the suitability of FKM seals for long-term use in coolant systems, with implications for material selection and design in demanding applications. This research contributes to the development of durable sealing solutions, ensuring reliability and safety in systems utilizing ethylene glycol-based coolants.  Keywords:  FKM, Volume Expansion, ASTM D471 ]]></description>
      <pubDate>Tue, 23 Jun 2026 13:36:31 GMT</pubDate>
      <guid>https://trid.trb.org/View/2712142</guid>
    </item>
    <item>
      <title>Coolant Pump Weep Chamber 3D CFD Transient Simulation for Predicting Coolant Evaporation</title>
      <link>https://trid.trb.org/View/2692135</link>
      <description><![CDATA[This paper presents transient, complex, multi-species, multiphase, 3D CFD transient simulation of engine coolant pump weep chamber for predicting coolant evaporation. The engine coolant pump contains a rotating mechanical face seal to prevent liquid coolant leakage at the rotating interface. During normal engine operation, a small amount of coolant vapor is expressed by this rotating seal; this vapor can condense on solid surfaces within the weep chamber. The coolant collected in weep chamber evaporates from the chamber and exits out of the weep chamber in vapor form. Evaporation rate of the coolant is a primary factor deciding weep chamber size. Evaporation rate of coolant depends on several factors – ambient humidity, ambient temperature, flow of air in and out of the weep chamber, pump temperature, and pump rotational speed. Weep chamber is small in dimensions (~ 100 cm^3) and dependence of coolant evaporation on several factors results in necessity of an accurate and predictive simulation methodology while designing a coolant pump. The simulation of evaporation is challenging due to need of modeling multiple species, multiple phases, and transient physics. In current work, an innovative 3D CFD simulation approach for predicting coolant evaporation in weep chamber is developed. The simulation approach can account for variation of ambient conditions, pump speed, coolant quantity, and coolant temperature. Evaporation rate prediction from the simulation is compared with a coolant pump evaporation rig test data and the results are found to be correlating within engineering accuracy. The simulation approach will be helpful in coolant pump design development work for determining design features of a weep chamber.]]></description>
      <pubDate>Thu, 28 May 2026 17:09:30 GMT</pubDate>
      <guid>https://trid.trb.org/View/2692135</guid>
    </item>
    <item>
      <title>Hierarchical Climate Control Framework for Electric Vehicles Considering Door-Opening Event</title>
      <link>https://trid.trb.org/View/2659141</link>
      <description><![CDATA[This paper presents a control-oriented model for door-opening scenarios in commercial electric vehicles (EVs), a common real-world issue. We developed and validated a simulation model to handle door-opening interruptions in a real EV. Using the developed model, we compared four heating controllers: (i) the proposed hierarchical nonlinear model predictive controller, incorporating a unique coolant-dividing layer and a component for regulating cabin air inflow based on door-opening signals; (ii) a single model predictive controller (MPC) for coolant division combined with a rule-based cabin air controller; (iii) a rule-based coolant-dividing controller integrated with a cabin air inflow MPC; and (iv) a conventional rule-based controller. Under ambient temperatures of 0, 10, and 20 ${}^{\circ }$C, our hierarchical controller reduced the temperature drops by 7.2, 9.5, and 10.92 ${}^{\circ }$C, respectively, in the cabin section where door-opening occurred, compared with the worst-performing controller in each scenario. Furthermore, our strategy significantly reduced temperature overshooting during recovery, achieving reductions of 84–87%, 60.8–83.8%, and 57.7–66.9% at 0, 10, and 20 ${}^{\circ }$C, respectively, in various cabin sections. These results demonstrate the potential of our strategy to enhance passenger thermal comfort across the vehicle, providing valuable insights for future thermal management strategies in commercial EVs.]]></description>
      <pubDate>Wed, 29 Apr 2026 09:10:07 GMT</pubDate>
      <guid>https://trid.trb.org/View/2659141</guid>
    </item>
    <item>
      <title>Optimization of Engine Cooling System for Improved Fuel Efficiency and Vehicle Marketability</title>
      <link>https://trid.trb.org/View/2692288</link>
      <description><![CDATA[Effective thermal management in internal combustion engines is essential for meeting increasingly stringent emissions regulations and achieving fuel efficiency improvements. This study introduces a novel and comprehensive approach to optimize engine thermal management by addressing key system components, including coolant circuit design, Integrated Thermal Management Module (ITM) control strategies, port-specific flow management, zero-flow operation techniques, and HVAC (Heating, Ventilation, and Air Conditioning) settings standardization. Unlike previously published works, this study focuses on reducing coolant circuit thermal mass to accelerate engine and component warm-up, refining ITM control logic through linear mapping and advanced signal filtering for precision, and enhancing zero-flow operation for minimizing lubricant oil dilution during start-up and reducing heat loss under low ambient conditions. Additional optimizations include port-specific adjustments and radiator flow distribution strategies to improve system responsiveness and fuel economy. Standardized HVAC configurations were implemented to ensure reproducibility across WLTP vehicle and bench testing scenarios. The methodology validated key improvements through rigorous testing on a newly developed engine platform and demonstrated scalability by successfully integrating these measures into vehicles designed to comply with EU7 regulations. Results indicate substantial gains in warm-up performance, coolant temperature control stability, energy efficiency, and regulatory compliance. Furthermore, these advancements underscore their practical application for automakers seeking novel solutions to meet evolving environmental standards and enhance market competitiveness. Overall, this study presents a set of scalable and widely applicable strategies for modern spark-ignition engines, supporting both new engine development and optimization of existing engines, while addressing global fuel-efficiency and emissions challenges effectively.]]></description>
      <pubDate>Tue, 14 Apr 2026 15:11:25 GMT</pubDate>
      <guid>https://trid.trb.org/View/2692288</guid>
    </item>
    <item>
      <title>Effect of Renewable Fuel Blends on Particulate Emissions in Warm-Up Conditions in a GDI Engine</title>
      <link>https://trid.trb.org/View/2692287</link>
      <description><![CDATA[Renewable gasoline offers significant benefits in reducing greenhouse gas (GHG) emissions. In this study, five gasolines with different renewable hydrocarbon classes and varying distillation curves were taken to investigate their effect on particle number (PN) emissions in a spark-ignition GDI engine at 10 bar indicated mean effective pressure (IMEP) and 2000 rpm. The engine coolant temperature was varied from 90°C to 35°C to investigate the effect of fuel evaporation on soot formation. Injectors with various spray plume targets and start of injection (SOI) timing (300° and 260° bTDC) were used to assess how different gasolines affect engine performance and to determine engine calibration requirements. A simplified transient cycle examines how engine motoring influences PN emissions for test gasolines. A high-speed camera and endoscope were used to identify the sources of soot during fuel combustion. Simulations were done to assess the quality of fuel-air mixing in support of the experimental data. The results revealed that the type of hydrocarbons in gasoline was crucially affecting PN emissions. Particles with >10 nm increased with increasing fuel’s aromatics. Paraffin-rich gasoline showed 71% and 98% lower PN than aromatics-rich gasoline under hot and cold engine conditions. Paraffin-rich gasoline showed lower PN in cold tests than in hot tests with retarded SOI. Replacing ~10% paraffins with olefins and naphthene reduced >10 nm PN by 15-77%. However, replacing 19% of paraffins with olefins and naphthene increases PN emissions. Optimal SOI timing reduces PN by 80% for aromatics-rich gasoline. Fuel consumption and hydrocarbon (HC) emissions increased with increasing aromatics and paraffins in gasoline under cold conditions. Yellow flames on the piston top and near the injector tip were the primary sources of soot. Simulation results showed that the liquid fuel mass increased by 14% when the coolant temperature was reduced by 55 K.]]></description>
      <pubDate>Tue, 14 Apr 2026 15:11:25 GMT</pubDate>
      <guid>https://trid.trb.org/View/2692287</guid>
    </item>
    <item>
      <title>Identifying Pressure Drop and Heat Transfer Correlations for a Liquid-Cooled Lithium-Ion Battery Pack Model of Electric Vehicles under Hot-Cold Driving</title>
      <link>https://trid.trb.org/View/2692189</link>
      <description><![CDATA[The performance of a full battery pack with its effective thermal management system (BTMS) depends on coolant flow and heat transfer characteristics inside the pack. To develop a full BTMS using model-based design (MBD), the model must capture the coolant pressure drop ??? and heat-exchange performance from the cell to ambient air via the coolant, cooling flow channels, air gaps, and pack cases. Predicting battery pack responses (i.e., voltage, SOC, temperature) under all weather conditions is a challenge, as a complete pack contains several hundred to thousands of cells, coolant lines, coolant line bends, and coolant channels. This work presents a detailed approach to identifying heat transfer and ?P correlations that can capture the real-time thermal-electrical performance of a mass-produced LIB pack under constant speed (in winter) and transient driving (in summer). A vehicle test is conducted using a Tesla Model Y, 2-motor model equipped with a 75-kWh LIB pack. The LIB pack's thermal and electrical performance is recorded at 60 km/h under cold conditions and during transient driving in summer. The pack is based on the 2RC equivalent circuit model, reduced from the P2D-based NCA/Gr-SiOx Li-ion cell, to accelerate simulation times at the pack and vehicle levels. The approach to identifying ?P and heat transfer correlations are discussed, with pack model validations under coolant temperatures ranging from 0 to 40 °C and coolant flow rates of 4 to 14 L/min. The thermal and electrical performances (voltage, SOC, ?P, and temperatures of the coolant, bricks, and modules) of the high-fidelity battery pack model are validated against vehicle test data at 60 km/h driving (ambient temperature Ta = -10 °C) and repeated FTP+HWFET cycle (Ta = 30°C). The whole pack model achieves an average accuracy of 90%, and this work can serve as a guideline for designing battery packs with their BTMS using MBD.]]></description>
      <pubDate>Tue, 14 Apr 2026 15:11:24 GMT</pubDate>
      <guid>https://trid.trb.org/View/2692189</guid>
    </item>
    <item>
      <title>Thermal Management Simulation of Liquid-Cooled Energy Storage Batteries Using a Reduced-Order Model</title>
      <link>https://trid.trb.org/View/2691936</link>
      <description><![CDATA[Linear time-invariant (LTI) reduced-order models (ROMs) have been widely used in battery thermal management simulations due to their low hardware requirements, high computational efficiency, and good accuracy. However, the inherent assumption of LTI behavior limits their applicability in scenarios with varying coolant flow rates, where this assumption is no longer valid. To address this limitation, a novel ROM is developed by decomposing the entire battery thermal system into two subsystems. All solid components are modeled as a traditional LTI ROM, while the coolant channel is represented using Newton’s cooling law. The two subsystems are then coupled through the exchange of heat transfer rate and temperature at the fluid–solid interface between the coolant and the cold plate. Model fidelity is further enhanced by introducing a spatially distributed heat flux during the generation of the LTI ROM for solid components. Validation is performed against CFD simulations at both module and pack levels, under constant and varying flow rates. The results demonstrate that the proposed ROM achieves high accuracy while requiring several orders of magnitude less computational time than the corresponding CFD models.]]></description>
      <pubDate>Tue, 14 Apr 2026 15:11:22 GMT</pubDate>
      <guid>https://trid.trb.org/View/2691936</guid>
    </item>
  </channel>
</rss>