FREQUENCY DOMAIN ANALYSIS FOR THE TENSION IN A TAUT MOORING LINE
The report provides a frequency domain analysis for the tension in long, taut mooring lines. The analysis considers both the steady state and dynamic conditions. Computer programs for the analysis of both cases are included. The requirement of linearity of the system evident in frequency domain analysis calls for linearization of such features as drag and internal damping. These matters are dealt with and the order of practical relevance discussed in a quantitative manner. (Author)
-
Corporate Authors:
University of Washington, Seattle
Department of Civil and Environmental Engineering, P.O. Box 352700
Seattle, WA United States 98195-2700 -
Authors:
- Hong, S T
- Publication Date: 1972-7
Media Info
- Pagination: 82 p.
Subject/Index Terms
- TRT Terms: Cables; Damping (Physics); Drag; Dynamics; Mooring cables
- Old TRIS Terms: Cable drag; Cable dynamics; Vibrating cables
- Subject Areas: Marine Transportation; Terminals and Facilities;
Filing Info
- Accession Number: 00044248
- Record Type: Publication
- Source Agency: National Technical Information Service
- Report/Paper Numbers: SM71-1
- Contract Numbers: N00014-67A-0103-0014
- Files: TRIS
- Created Date: May 11 1973 12:00AM