Performance of a Bridge Deck with Glass Fiber Reinforced Polymer Bars as the Top Mat of Reinforcement
The purpose of this research was to investigate the performance of glass fiber reinforced polymer (GFRP) bars as reinforcement for concrete decks. Today's rapid bridge deck deterioration is calling for a replacement for steel reinforcement. The advantages of GFRP such as its high tensile strength, light weight, and resistance to corrosion make it an attractive alternative to steel. The deck of one end-span of the Gills Creek Bridge was constructed with GFRP bars as the top mat and epoxy-coated steel bars as the bottom mat. Live load tests wee performed in 2003, shortly after completion of construction, and again in 2004. In addition, tests were performed on the deck of the opposite end-span, which had all epoxy-coated steel reinforcing. The results of these tests were used to evaluate the girder distribution factors and impact factors of a GFRP reinforced bridge deck. In addition, a comparison of the results from the two test periods gives an indication of any changes in strains in the GFRP bars and if the deck is behaving differently than when first installed. The results were compared to the design standards specified by the American Concrete Institute in the "Guide for the Design and Construction of Concrete Reinforced with FRP Bar" to determine if the GFRP reinforcement had any significant influence on overall bridge behavior. There were no significant differences in the behavior of the deck after 1 year of service and there was no visible cracking. The behavior of the two end-spans was similar, and the measured girder distribution factors were less than the AASHTO design recommendations. The impact factors were less than design values for the 2003 tests but higher than design values for the 2004 tests. Stresses in the GFRP reinforcing bars were much less than the design allowable stress and did not change significantly after 1 year of service. The strain gauges, vibrating wire gauges, and thermocouples in the bridge deck were monitored for approximately 1 year using a permanent data acquisition system. Daily, monthly, and long-term fluctuations in temperature and stresses were examined. The vibrating wire gauges were more reliable than the electrical resistance strain gauges, and the main influence on strain changes was temperature fluctuation. A cost/benefit analysis of using GFRP bars indicates their high initial costs are justified when compared to the costs of a concrete overlay.
- Record URL:
-
- Record URL:
-
Corporate Authors:
Virginia Transportation Research Council
530 Edgemont Road
Charlottesville, VA United States 22903Virginia Department of Transportation
1401 East Broad Street
Richmond, VA United States 23219Federal Highway Administration
1200 New Jersey Avenue, SE
Washington, DC United States 20590 -
Authors:
- Phillips, Kimberly A
- Harlan, Matthew
- Roberts-Wollmann, Carin L
- Cousins, Thomas E
- Publication Date: 2005-6
Language
- English
Media Info
- Media Type: Print
- Edition: Final Contract Report
- Features: Figures; Photos; References; Tables;
- Pagination: 68p
Subject/Index Terms
- TRT Terms: Benefit cost analysis; Bridge decks; Corrosion resistance; Design standards; Epoxy coatings; Glass fiber reinforced plastics; Lightweight materials; Load tests; Mechanical strain; Monitoring; Performance; Reinforced concrete; Reinforcing bars; Steel; Strain gages; Stresses; Temperature; Tensile strength
- Uncontrolled Terms: Distribution factors; Structural behavior; Vibrating wire gages