STRUCTURAL IMPLICATIONS OF GOOD SOUND INSULATION
The examples shown in the paper illustrate the way in which structural transmission limits the attainable insulation. The use of vibration isolation can reduce the effect of such paths and sound insulation values in excess of 96dB average sound level difference have been measured in special cases.
-
Corporate Authors:
Society of Environmental Engineers
4 Harmsworth Way
London N20 8JU, England -
Authors:
- Burd, A
- Publication Date: 1977-9
Media Info
- Features: References;
- Pagination: p. 27-30
-
Serial:
- Society of Environmental Engineers, Journal of
- Volume: 16
- Issue Number: 3
- Publisher: Society of Environmental Engineers
Subject/Index Terms
- TRT Terms: Acoustic measuring instruments; Acoustics; Measurement; Noise control; Sound attenuation; Sound insulating materials; Structural design; Vibration control
- Old TRIS Terms: Acoustic measurement; Acoustic variables measurement; Sound insulation
- Subject Areas: Environment; Railroads;
Filing Info
- Accession Number: 00173162
- Record Type: Publication
- Source Agency: Engineering Index
- Files: TRIS
- Created Date: Apr 26 1978 12:00AM