NON-INSULATED TRACK CIRCUITS WITH DIRECT-COUPLED RECEIVER: ANALYSIS RELATIONS, METHOD OF CALCULATION
Expressions of transfer admittances in normal and shunt operation for direct-coupled non-insulated track circuits with and without capacitive charging are given. A method is proposed to determine the maximum length and optimum terminal resistances; on the basis of this determination conclusions can be drawn about capacitive charging. The computer program is run on an IBM 360 computer.
-
Corporate Authors:
International Railway Congress Association
17-21 rue de Louvrain
1000 Brussels, Belgium -
Authors:
- Iancu, O D
- Giuhat, R
- Publication Date: 1976-11
Media Info
- Features: Figures; References;
- Pagination: p. 638-645
-
Serial:
- RAIL INTERNATIONAL
- Volume: 7 N
- Issue Number: 11
Subject/Index Terms
- TRT Terms: Automatic train protection; Computer programs; Electric circuits; Signaling; Track circuits
- Old TRIS Terms: Audio frequency track circuits; Circuit design; Ibm 360; Train protection
- Subject Areas: Operations and Traffic Management; Railroads;
Filing Info
- Accession Number: 00149451
- Record Type: Publication
- Source Agency: Rail International
- Files: TRIS
- Created Date: Apr 27 1977 12:00AM