FIELD MEASUREMENT OF JACKET MEMBER STRUCTURAL PROPERTIES

This paper documents a fabrication yard measurement program carried out to measure jacket member damping and end fixity. These parameters are important in characterising vortex-induced vibration response. The results confirm the expectation that jacket members generally have low damping, frequently less than 0.3 percent of critical. The data indicates a range of end fixities can occur, depending on member end conditions, with an average fixity of about 70 percent typically observed. See also the following Abstract.

  • Supplemental Notes:
    • "OTC '89", 21st Annual Offshore Technology Conference held Houston May 1-4th 1989, Vol. 4, p.569 [8 pp., 3 ref., 2 tab., 8 fig.]
  • Authors:
    • Koch, S P
  • Conference:
  • Publication Date: 1989

Language

  • English

Subject/Index Terms

Filing Info

  • Accession Number: 00696129
  • Record Type: Publication
  • Source Agency: British Maritime Technology
  • Files: TRIS
  • Created Date: Aug 14 1995 12:00AM