CABLES OVER THE MISSISSIPPI
The design is described of the $50 million Great River Bridge, an asymmetrical cable-stayed bridge, which was successfully built on an inconvenient site to improve navigation on the Mississippi. The reasons for using a cable-stayed bridge with an asymmetric arrangement and single tower are noted. Design issues involved in the deck configuration and cable arrangement are noted. The use of the second order approach with loading, piers of H-piles, the moment resistant frame of the tower, the stay cables, and prefabrication are described.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/oclc/10480594
-
Corporate Authors:
American Society of Civil Engineers
345 East 47th Street
New York, NY United States 10017-2398 -
Authors:
- Petzold, E H
- Publication Date: 1994-2
Language
- English
Media Info
- Pagination: p. 62-65
-
Serial:
- Civil Engineering
- Volume: 64
- Issue Number: 2
- Publisher: American Society of Civil Engineers
- ISSN: 0885-7024
- Serial URL: http://www.pubs.asce.org/ceonline/newce/html
Subject/Index Terms
- TRT Terms: Bridge design; Bridges; Cable stayed bridges; Loads; Navigation; Structural design; Support piles
- Uncontrolled Terms: Loading
- Geographic Terms: Mississippi
- Old TRIS Terms: H bearing piles; Mississppi
- Subject Areas: Bridges and other structures; Design; Highways; I24: Design of Bridges and Retaining Walls;
Filing Info
- Accession Number: 00643693
- Record Type: Publication
- Files: TRIS, ATRI
- Created Date: Mar 3 1994 12:00AM