INVESTIGATION OF LABORATORY TEST METHODS TO DETERMINE CURING RATE OF ASPHALT EMULSION. FINAL REPORT

This study resulted from reports of emulsions used in the construction of chip seals taking an excessively long time to cure. This led to shelling of the stone from the pavement within a few hours or even days after construction. These failures were often attributed to the emulsion formulation even though the material passed all specifications. The objective of this study was to develop a test method which would identify the curing time of apshalt emulsions ensuring better field performance. Several test methods were investigated which led to the development of the TTI Cohesion Test. The concept for the test was derived from an existing test used for determining the cure time for slurry seals. The TTI Cohesion Test requires the preparation of an emulsion chip seal sample in the laboratory. The sample is then placed beneath a pneumatically actuated rubber foot, and a pressure is applied to the sample. The rubber foot is twisted by means of a motor which is connected to a torque sensor thereby supplying a plot of torque versus displacement of the rubber foot. The test is repeated at different time intervals and an undisturbed site on the sample is selected for each time-interval test. The testing is continued until the torpue remains constant which indicates the sample has cured. Results from laboratory testing indicated that the TTI Cohesion Test can be used to monitor the curing process of asphalt emulsion chip seal samples. Two parameters taken from the Cohesion Test may be used as qualitative indicators of the curing process of asphalt emulsion chip seals. These parameters are called Curing Index and t sub 95. The Curing Index is the percentage of the total cure that has occurred at six hours. The t sub 95 value is the time required to reach 95% of the maximum torque value or the time at which 95% of the total cure has occurred. Rapid-setting emulsion laboratory chip seals should have Curing Indices of 75% or more. In other words, in six hours, a rapid-setting emulsion laboratory chip seal should have reached 75% of its total cure. Rapid-setting emulsion laboratory chip seals should have t sub 95 values of 35 hours or less. In other words, a rapid-setting emulsion laboratory chip seal should have reached 95% of its total cure within 35 hours.

Language

  • English

Media Info

  • Features: Appendices; Figures; Photos; References; Tables;
  • Pagination: 121 p.

Subject/Index Terms

Filing Info

  • Accession Number: 00625214
  • Record Type: Publication
  • Report/Paper Numbers: FHWA/TX-92+1157-1F, Res Rept 1157-1F, TTI: 2-9-87-1157
  • Contract Numbers: Study 2-9-87-1157
  • Files: TRIS, USDOT, STATEDOT
  • Created Date: Oct 27 1996 12:00AM