THE EFFECTS OF REINFORCEMENT DETAILING ON THE PROTECTION OF REINFORCED CONCRETE BEAM/COLUMN CONNECTIONS . PROTECTION OF CONCRETE. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE HELD AT THE UNIVERSITY OF DUNDEE, SEPTEMBER 11-13, 1990

This paper describes laboratory tests on fifteen reinforced concrete external beam/column connections. Both the beam and the column reinforcement were internally strain gauged with, typically, a total of 230 strain gauges being installed in each specimen. The tests produced very detailed information concerning strain and bond stress distributions in the connection zone for each of the three detailing arrangements investigated - bending the beam tension steel down into the column, bending it up into the column, or bending it back into the beam to form a U' bar. Bending the beam tension steel down into the column was best able to transfer load by bond at all stages in the load history of the specimens. The U' bar detail was satisfactory, whilst the results indicated that bending the beam tension steel up into the column should be avoided. (Author/TRRL)

  • Availability:
  • Corporate Authors:

    E and F Spon Limited

    2-6 Boundary Road
    London,   England 
  • Authors:
    • Scott, R H
    • Gill, PAT
  • Publication Date: 1990

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00620017
  • Record Type: Publication
  • Source Agency: Transport Research Laboratory
  • ISBN: O-419-15490-6
  • Files: ITRD, TRIS
  • Created Date: Mar 31 1992 12:00AM