QUESTIONS AND ANSWERS ON ASTM A 706 REINFORCING BARS

This question-and-answer article based on dialogue with architect-engineers and constructors, is based on a Concrete Reinforcing Steel Instititute Engineering data report. In it, the major requirements in the ASTM A 706 specification are discussed, and information on the use and availability of low-alloy reinforcing bars is presented. The questions and answers cover the development of specification, mechanical properties, weldability, usage, and availability. A total of 22 questions are asked and answered in these areas. It is noted that if the reinforcing bars for a project do not require controlled tensile properties and/or weldability, other types must be specified. Also, before comleting a design or specifying A 706 bars, the designer should investigate local availability.

Media Info

  • Features: Figures; References; Tables;
  • Pagination: p. 54-57
  • Serial:
    • Concrete International
    • Volume: 13
    • Issue Number: 7
    • Publisher: American Concrete Institute (ACI)
    • ISSN: 0162-4075

Subject/Index Terms

Filing Info

  • Accession Number: 00611178
  • Record Type: Publication
  • Files: TRIS
  • Created Date: Aug 31 1991 12:00AM