QUESTIONS AND ANSWERS ON ASTM A 706 REINFORCING BARS
This question-and-answer article based on dialogue with architect-engineers and constructors, is based on a Concrete Reinforcing Steel Instititute Engineering data report. In it, the major requirements in the ASTM A 706 specification are discussed, and information on the use and availability of low-alloy reinforcing bars is presented. The questions and answers cover the development of specification, mechanical properties, weldability, usage, and availability. A total of 22 questions are asked and answered in these areas. It is noted that if the reinforcing bars for a project do not require controlled tensile properties and/or weldability, other types must be specified. Also, before comleting a design or specifying A 706 bars, the designer should investigate local availability.
- Availability:
-
Corporate Authors:
P.O. Box 19150, Redford Station, 22400 Seven Mile Road
Detroit, MI United States 48219 -
Authors:
- Gustafson, D P
- Felder, A L
- Publication Date: 1991-7
Media Info
- Features: Figures; References; Tables;
- Pagination: p. 54-57
-
Serial:
- Concrete International
- Volume: 13
- Issue Number: 7
- Publisher: American Concrete Institute (ACI)
- ISSN: 0162-4075
Subject/Index Terms
- TRT Terms: Alloys; Reinforcing bars; Specifications; Welding
- Uncontrolled Terms: Rebars; Weldability
- Subject Areas: Highways; Materials; I32: Concrete;
Filing Info
- Accession Number: 00611178
- Record Type: Publication
- Files: TRIS
- Created Date: Aug 31 1991 12:00AM