THERMAL RESPONSE OF A SMALL SCALE CASK-LIKE TEST ARTICLE TO THREE DIFFERENT HIGH TEMPERATURE ENVIRONMENTS. FINAL REPORT
The report describes the test series conducted to assess the thermal response of a small scale, cask-like test article to three different thermal environments: an 800 deg C, 30-min radiant heat environment; an 870 deg C, 100-min radiant heat environment; and an enclosed engulfing fire environment of approximately 100-min duration. Results indicated that the average total heat input to a cask-like test article was 140 MJ/sq m for an 870 deg C, 100-min radiant heat environment; 88 MJ/sq m for an 800 deg C, 30-min radiant heat environment; and 125 MJ/sq m for enclosed engulfing fire for an approximate 100-min duration. Results are specific to the test article geometry that was tested and are not applicable to real shipping cask geometries.
- Record URL:
-
-
Corporate Authors:
Sandia National Laboratories
P.O. Box 5800
Albuquerque, NM United States 87185Federal Railroad Administration
1200 New Jersey Avenue, SE
Washington, DC United States 20590 -
Authors:
- Longenbaugh, R S
- Sanchez, L C
- Mahoney, A R
- Publication Date: 1990-2
Media Info
- Media Type: Digital/other
- Pagination: 139 p.
Subject/Index Terms
- TRT Terms: Containers; Fires; Flammability; High temperature; Radioactive wastes; Railroad transportation; Testing; Thermal stresses
- Uncontrolled Terms: Thermal response
- Old TRIS Terms: Test results
- Subject Areas: Highways; Railroads; Safety and Human Factors;
Filing Info
- Accession Number: 00600455
- Record Type: Publication
- Source Agency: National Technical Information Service
- Report/Paper Numbers: DOT/FRA/ORD-90/01
- Contract Numbers: DTFR53-86-X-00035
- Files: TRIS, USDOT
- Created Date: Oct 31 1990 12:00AM